2012
DOI: 10.1016/j.jcrs.2011.12.040
|View full text |Cite
|
Sign up to set email alerts
|

Objective comparison of 4 nonlongitudinal ultrasound modalities regarding efficiency and chatter

Abstract: Objective comparison of phacoemulsification efficiency and chatter found that optimized Ozil-IP and Ellips-FX were similar in both parameters and in general, both performed better than preceding technology. The study parameters can significantly affect efficiency and chatter, which strongly correlate with each other.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
37
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 51 publications
(38 citation statements)
references
References 7 publications
(5 reference statements)
1
37
0
Order By: Relevance
“…6 The lens cubes were then transferred into 1 container containing BSS. The lens cubes were washed 3 times with BSS and allowed to equilibrate in 10 mL BSS overnight at room temperature.…”
Section: This Was An Experimental Study Involving Laboratory Researchmentioning
confidence: 99%
“…6 The lens cubes were then transferred into 1 container containing BSS. The lens cubes were washed 3 times with BSS and allowed to equilibrate in 10 mL BSS overnight at room temperature.…”
Section: This Was An Experimental Study Involving Laboratory Researchmentioning
confidence: 99%
“…Our group has created original laboratory methods using brunescent human nuclei from Tanzanian patients in order to further investigate and optimize such technology [6]. These lenses were 3+ to 4+ in hardness, and thus are suitable for testing efficiency.…”
Section: Discussionmentioning
confidence: 99%
“…Another study showed that a 0.9 mm, 30-degree angled tip is most efficient when compared to similar 1.1 mm and 0.7 mm tips [8]. This is just a sampling of the many papers that have clarified clinical arguments about superiority in instrumentation definitively and for the first time [5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23]. Figure 1: Effect of time on efficiency using the humidity chamber method.…”
Section: Discussionmentioning
confidence: 99%
“…Theoretically, different angles impact surface area available for cataract engagement, ultrasound modality choice, time to occlusion and risk of capsular breakage [1]. DeMill et al [2] and Oakey et al [3] have shown that even small adjustments in these parameters can lead to drastic changes in both efficiency and chatter during lens removal; however, evidence for bevel tip angulation and its impact on efficiency and chatter is lacking. Furthermore, when choosing bevel angle, surgeons are often guided principally by personal preference, others by their opinions and training.…”
Section: Introductionmentioning
confidence: 99%