2013 Annual IEEE India Conference (INDICON) 2013
DOI: 10.1109/indcon.2013.6726081
|View full text |Cite
|
Sign up to set email alerts
|

Objective evaluation of radial pulse signal

Abstract: Radial pulse signal analysis is an extensively explored diagnostic tool in traditional Indian as well as Chinese school of medicine. Objective examination of radial pulse signal and effect on its temporal domain characteristics features, as a result of activities conducted on healthy individuals have been evaluated.Radial pulse analysis, using pulse peak-peak variability-basis, on lines similar to heart rate variability, has been performed. Analysis of radial pulse signal for extracting respiration, thermoregu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2016
2016

Publication Types

Select...
1
1

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…Changes in contour shape as well as intensity of the pressure pulse waveform are caused due to decreasing arterial/capillary diameters, decreasing pressure and are also contributed by the total distensibility of the arterial tree [14]. On lines similar to authors previous works [10,11,12], a capacitance based pulse sensing mechanism has been used for signal sensing ( Figure 1). An electret capacitive pick-up (typical CMA-4544PF-W available from DigiKey part no 102-1721-ND), and having a near flat frequency response up-to 20 kHz is used for sensing the radial pulse perturbations.…”
Section: Pulse Sensing Mechanismmentioning
confidence: 70%
See 2 more Smart Citations
“…Changes in contour shape as well as intensity of the pressure pulse waveform are caused due to decreasing arterial/capillary diameters, decreasing pressure and are also contributed by the total distensibility of the arterial tree [14]. On lines similar to authors previous works [10,11,12], a capacitance based pulse sensing mechanism has been used for signal sensing ( Figure 1). An electret capacitive pick-up (typical CMA-4544PF-W available from DigiKey part no 102-1721-ND), and having a near flat frequency response up-to 20 kHz is used for sensing the radial pulse perturbations.…”
Section: Pulse Sensing Mechanismmentioning
confidence: 70%
“…Conventionally TIM physicians solely rely on sense perception for Va, Pt and Kp identification and quantification. The present study, similar to earlier [10,11,12], attempts to identify signal processing based measures/ parameters for identifying Vt, Pt and Kp humors for achieving an objective outlook. This can help in the realisation of a low cost, non-invasive diagnostic tool as a value added aid for physicians.…”
Section: Introductionmentioning
confidence: 89%
See 1 more Smart Citation