2011
DOI: 10.1134/s1063785011040043
|View full text |Cite
|
Sign up to set email alerts
|

Observation of filaments on the globus-M tokamak by Doppler reflectometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
31
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 3 publications
2
31
0
Order By: Relevance
“…After normalization BQFs for the both linear and nonlinear look similar as it is shown in figure 2(b) and the relation for the Doppler shift k⊥ = k х = 2k 0 sinα is preserved correspondingly. It is important to note that similarly shaped BQOs were observed in experiments on the Globus-M tokamak (see Figure 2c) [3,4]. The similarity of BQFs in the linear and nonlinear case, on the one hand, explains the fact that similar BQFs were observed The calculations for the case of multiple frequency probing were carried out for the same radial position of the moving filament r = 9cm.…”
Section: Results Of Simulationssupporting
confidence: 61%
See 2 more Smart Citations
“…After normalization BQFs for the both linear and nonlinear look similar as it is shown in figure 2(b) and the relation for the Doppler shift k⊥ = k х = 2k 0 sinα is preserved correspondingly. It is important to note that similarly shaped BQOs were observed in experiments on the Globus-M tokamak (see Figure 2c) [3,4]. The similarity of BQFs in the linear and nonlinear case, on the one hand, explains the fact that similar BQFs were observed The calculations for the case of multiple frequency probing were carried out for the same radial position of the moving filament r = 9cm.…”
Section: Results Of Simulationssupporting
confidence: 61%
“…Various diagnostics are employed for this purpose. A few years ago the authors proposed to use the Doppler backscattering (DBS) method for filaments investigation in the Globus-M spherical tokamak [3,4]. Later this diagnosis was successfully applied to the study of the filaments in the ASDEX Upgrade tokamak [5,6].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The first implementation of DBS on a spherical tokamak was carried out on Globus-M [31]. There are specific requirements for DBS application in a spherical tokamak that is characterized by a significant pitch angle (more than 20 • ) at the low magnetic field side.…”
Section: Doppler Backscattering On Globus-m 21 Dbs Systemsmentioning
confidence: 99%
“…Such an implementation is possible when the poloidal size of the filaments is close to π/k ⊥ (1-3 cm in the case of DBS on Globus-M), where k ⊥ is the wave vector of the incident wave in the cutoff region. Such filaments were discovered using DBS inside the separatrix in ELMy H-mode with NBI [31,57] and in Ohmic H-mode with high MHD activity [58,59]. Filaments were observed as a sequence of bursts of quasi-coherent fluctuations (BQFs) in the IQ DBS signals.…”
Section: Filamentsmentioning
confidence: 99%