1989
DOI: 10.1007/bf01552841
|View full text |Cite
|
Sign up to set email alerts
|

Observations of the performance of buildings during the 1985 Mexico earthquake, and structural design implications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(16 citation statements)
references
References 2 publications
0
16
0
Order By: Relevance
“…In the 1976 Tangshan earthquake, the instantaneous settlement of 3-4-story buildings reached 10-30 cm in Tanggu area, and the differential settlement kept developing several years after the earthquake [9] . Such phenomena were also found in the 1957 and 1985 Mexico Earthquakes [10] , and the 1978 Miyagi-oki Earthquake [11] . Figure 1 shows the seismic settlements of a building foundation during and after the 1957 Mexico City Earthquake.…”
Section: Introductionmentioning
confidence: 98%
“…In the 1976 Tangshan earthquake, the instantaneous settlement of 3-4-story buildings reached 10-30 cm in Tanggu area, and the differential settlement kept developing several years after the earthquake [9] . Such phenomena were also found in the 1957 and 1985 Mexico Earthquakes [10] , and the 1978 Miyagi-oki Earthquake [11] . Figure 1 shows the seismic settlements of a building foundation during and after the 1957 Mexico City Earthquake.…”
Section: Introductionmentioning
confidence: 98%
“…There have been specific studies to investigate damage due to pounding for existing buildings and specific situations (Rosenblueth 1986;Scholl 1989;Kasai 1997;Jankowski, Wilde et al 2000;Raheem 2006;Jankowski 2007a;Raheem 2009;Mahmoud, Abd-Elhamed et al 2013;Raheem 2014). These reports highlighted the importance of adequate design for weaker buildings for which structural pounding can produce catastrophic damage.…”
Section: Linear Model and Basic Model Structurementioning
confidence: 99%
“…Many CBFs were destroyed and even collapsed in past earthquakes due to their poor performance. Regardless of the fact that numerous experimental and theoretical studies have been carried out for CBFs, the CBF system still suffers from various degrees of damage due to its poor ductility [3][4][5][6][7][8]. Thus, the CBFs constructed based on poor design guides in earlier days still attract the attention of researchers [9][10][11][12][13][14][15][16][17][18] CBFs in moderate seismic regions (MSRs) are typically designed using a response modification coefficient R equal to 3, which allows the seismic resistance detailing of a structure to be ignored, e.g., in the United States [19].…”
Section: Introductionmentioning
confidence: 99%