1999
DOI: 10.1016/s0142-0615(99)00005-8
|View full text |Cite
|
Sign up to set email alerts
|

Obtaining dynamic equivalents through the minimization of a line flows function

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…As introduced in refs. [7,9] and based on the classification by previous studies, [10][11][12][13] methods to create EDAM can be categorized in methods for networks with conventional generation only, i.e., coherency and modal-based approaches, [14,15] and for networks with both conventional generation and CBG. The latter is relevant for stability studies of future power systems dominated by CBG.…”
Section: Classificationmentioning
confidence: 99%
“…As introduced in refs. [7,9] and based on the classification by previous studies, [10][11][12][13] methods to create EDAM can be categorized in methods for networks with conventional generation only, i.e., coherency and modal-based approaches, [14,15] and for networks with both conventional generation and CBG. The latter is relevant for stability studies of future power systems dominated by CBG.…”
Section: Classificationmentioning
confidence: 99%
“…By introducing the conformable fractional derivative and the conformable fractional integral into two‐machine interconnected power system, the conformable fractional‐order two‐machine interconnected power system 40 is defined as {leftarrayTt0qx1=x2arrayTt0qx2=cx2+fx3+ρβsinx1arrayTt0qx3=ωx4arrayTt0qx4=ωx32.56804pt, where q is the order and c, f , ρ , β , and ω are the system parameters. The linear term, the nonlinear term, and the constant vector of the system are splited as []centerarrayLx1arrayLx2arrayLx3arrayLx4=[]centerarrayx2arraycx2+fx3arrayωx4arrayωx3,[]centerarrayNx1arrayNx2arrayNx3arrayNx4=[]centerarray0arrayβsinx1array0array0,[]centerarra...…”
Section: Solution Of Conformable Fractional Differential Equationsmentioning
confidence: 99%
“…In the equivalent system, equivalent generator represents dynamic effect of the external system on the internal system located at the boundary bus. When there are multiple boundary buses connecting the external system with the internal system, multiple generators are adopted to represent dynamic influence of the external system on the internal system, with an equivalent generator located at each boundary bus [18]. Detailed generator models have not received as much attention in system equivalents, even though the detailed models are important in power system dynamic analysis.…”
Section: A Dynamic Equivalent Modelmentioning
confidence: 99%