2003
DOI: 10.1227/01.neu.0000093427.89827.12
|View full text |Cite
|
Sign up to set email alerts
|

Occlusion of Experimental Aneurysms with Heparin-loaded, Microporous Stent Grafts

Abstract: The stent graft we have developed seems to be highly promising for the treatment of aneurysms, especially with respect to immediate termination of blood inflow for aneurysm occlusion and rapid endothelialization in the aneurysm neck.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2006
2006
2013
2013

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 18 publications
(22 citation statements)
references
References 35 publications
1
21
0
Order By: Relevance
“…This raises questions on how PMMPI interacts with MMPs at the liquid-solid interface or whether the MMPI binding to the zinc ion located at the active site of the MMP is a reversible reaction or not. Irrespective of these processes, however, the present results support the reasonable application of PMMPI as a coating for metal stents and polymer-covered stents 32,33 to prevent restenosis after stent implantation. An additional advantage is the extremely low drug concentrations in blood and high local concentration at the treatment site provided by this polymer, which is a potentially significant prerequisite for DES.…”
Section: Discussionsupporting
confidence: 65%
“…This raises questions on how PMMPI interacts with MMPs at the liquid-solid interface or whether the MMPI binding to the zinc ion located at the active site of the MMP is a reversible reaction or not. Irrespective of these processes, however, the present results support the reasonable application of PMMPI as a coating for metal stents and polymer-covered stents 32,33 to prevent restenosis after stent implantation. An additional advantage is the extremely low drug concentrations in blood and high local concentration at the treatment site provided by this polymer, which is a potentially significant prerequisite for DES.…”
Section: Discussionsupporting
confidence: 65%
“…20,21 As a stent platform, the Sendai stent (diameter: 4.5, 5.0, or 6.0 mm; length: 18 or 23 mm, Piolax), which is a self-expandable stent, was used. Segments of the Sendai stent are structured from 12 struts and each segment is linked at three joints.…”
Section: Fabrication Of Self-expandable Drug-eluting Covered Stentsmentioning
confidence: 99%
“…Our microporous membrane induces early endothelialization capable of secreting tissue plasminogen 11 within one week of stent graft implantation, 3 thereby avoiding early thrombosis and controlling mid- to long-term hyperplasia. 12 Polyurethane has excellent elastomeric properties and is clinically used as a material for manufacturing blood pumps and arterial grafts; it also exhibits no toxicity or little biodegradation.…”
Section: Discussionmentioning
confidence: 99%
“…Micropores are circular, with a pore diameter and interpore distance of 100 µm and 250 µm, respectively, such that they achieve an opening ratio of 23.6% (calculated) after full expansion. 3 The uncoated stent was a bare stent with an opening ratio of 86%. The outer surface of the film of the microporous stent grafts was coated with argatroban (500 µg/cm 2 ), which was applied using a methanol solution (1% w/v); the solvent was subsequently volatilized for physical adsorption.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation