2014
DOI: 10.1117/1.jbo.19.10.105008
|View full text |Cite
|
Sign up to set email alerts
|

Ocular temperature elevation induced by thresholdin vivoexposure to 1090-nm infrared radiation and associated heat diffusion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 15 publications
0
13
0
Order By: Relevance
“…18,19 The current findings that 96-W∕cm 2 1090-nm IRR with 1-h exposure does not result in direct damage in the lens if the temperature rise is <8°C implicates that IRR-induced cataract is caused by indirect heat absorption in tissues surrounding the lens or, alternatively, possibly by a local inflammatory reaction induced by temperature rise in tissues surrounding the lens, or both.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…18,19 The current findings that 96-W∕cm 2 1090-nm IRR with 1-h exposure does not result in direct damage in the lens if the temperature rise is <8°C implicates that IRR-induced cataract is caused by indirect heat absorption in tissues surrounding the lens or, alternatively, possibly by a local inflammatory reaction induced by temperature rise in tissues surrounding the lens, or both.…”
Section: Discussionmentioning
confidence: 95%
“…19 In the current experiment, we chose to record temperature at the limbus only to allow for high accuracy without any risk for mechanical cataract induction.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…28 In a follow-up experiment with the same exposure conditions, temperature measurements at the limbus and close to the optic nerve outside the sclera during the exposure demonstrated that the temperature increase at the limbus was around 10°C, supporting a thermally induced short delay onset damage. 29 In a subsequent experiment, exposures with the 1090 nm beam at 96 W/cm 2 in a 2 mm spot inside the dilated pupil of a living rat eye was delivered to different groups of animals with incrementing exposure time in the interval 10-60 min, the maximum radiant exposure corresponding to a radiant exposure dose of 340 kJ/cm 2 . One eye was exposed and the contralateral eye was kept not exposed as a control.…”
Section: Recent Experimental Investigation Of Near Irr Cataractmentioning
confidence: 99%