Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Thousands of offshore wells are planned to be permanently plugged and abandoned worldwide up to 2050. Fractures are known to occur and develop in the materials used as seals/plugs, creating channels that compromise P&A integrity. This risk is increased by the foreseeable use of oil and gas assets in CCS and hydrogen storage projects. Existing monitoring methods may fail to provide early warning of issues with plug integrity. There is presently no regulation in place on Norwegian Continental Shelf about long-term monitoring of permanently plugged and abandoned wells, however, this situation is likely to change in the future. Thus, cheap, and effective methods to monitor the integrity of long-term P&A of offshore wells are necessary. The existing technology for P&A is sufficiently mature to dramatically reduce the risk of a "catastrophic" failure in its deployment. Thus, if the integrity of permanent barriers is compromised, it is likely that this will happen through the establishment of micro-fractures where very small flowrates of reservoir fluids can escape or diffuse to the marine environment. If such early signs are detected, then a more thorough diagnose and mitigation campaign can be deployed in a timely manner. Tracer technology can provide this type of early warning. By including tracers in the P&A projects, either deploying a slug just before the installation of barriers, or embedded in the barrier material matrix, these substances will be detected in the waters around the plugged well head, if channels allow for the circulation of fluids between the bottom and top of the wells. Most (if not all) existing tracers are detectable in the ng/L (ppt) level, thus providing a warning system even if just diffusion occurs. The tracers qualified for use in oil & gas reservoirs are not exposed to the presence of materials used in plugs/barriers in P&A. Many of these materials (e.g., cement-based) exhibit surfaces with relatively high energies and activities. Thus, it is critical to evaluate tracer response for this type of new application. In the present document, we present an initial study to evaluate long-term stability and dynamic flooding properties of existing water-based tracers in the presence of Portland cement and CO2 originated ions. The stability experiments were performed at two different temperatures. The dynamic flooding properties were evaluated relatively to tritiated water in a reference barrier cell constructed with known defects. The cell used (referred to in the present document as plug) consisted of a well section with cemented casing (Portland), constructed on purpose to allow for fluid circulation in a "microannulus". Results show that further evaluation and development of the concept of using tracers as an early warning system for permanent P&A is necessary. However, of the 8 tested tracers, 4 exhibit an ideal or close to ideal flooding behavior in the microannulus system that open the doors to such an application. Results also suggest that tracer tests using conventional inter-well water tracers can be devised to assess the quality of both borehole and casing cementing in conventional well-completion operations.
Thousands of offshore wells are planned to be permanently plugged and abandoned worldwide up to 2050. Fractures are known to occur and develop in the materials used as seals/plugs, creating channels that compromise P&A integrity. This risk is increased by the foreseeable use of oil and gas assets in CCS and hydrogen storage projects. Existing monitoring methods may fail to provide early warning of issues with plug integrity. There is presently no regulation in place on Norwegian Continental Shelf about long-term monitoring of permanently plugged and abandoned wells, however, this situation is likely to change in the future. Thus, cheap, and effective methods to monitor the integrity of long-term P&A of offshore wells are necessary. The existing technology for P&A is sufficiently mature to dramatically reduce the risk of a "catastrophic" failure in its deployment. Thus, if the integrity of permanent barriers is compromised, it is likely that this will happen through the establishment of micro-fractures where very small flowrates of reservoir fluids can escape or diffuse to the marine environment. If such early signs are detected, then a more thorough diagnose and mitigation campaign can be deployed in a timely manner. Tracer technology can provide this type of early warning. By including tracers in the P&A projects, either deploying a slug just before the installation of barriers, or embedded in the barrier material matrix, these substances will be detected in the waters around the plugged well head, if channels allow for the circulation of fluids between the bottom and top of the wells. Most (if not all) existing tracers are detectable in the ng/L (ppt) level, thus providing a warning system even if just diffusion occurs. The tracers qualified for use in oil & gas reservoirs are not exposed to the presence of materials used in plugs/barriers in P&A. Many of these materials (e.g., cement-based) exhibit surfaces with relatively high energies and activities. Thus, it is critical to evaluate tracer response for this type of new application. In the present document, we present an initial study to evaluate long-term stability and dynamic flooding properties of existing water-based tracers in the presence of Portland cement and CO2 originated ions. The stability experiments were performed at two different temperatures. The dynamic flooding properties were evaluated relatively to tritiated water in a reference barrier cell constructed with known defects. The cell used (referred to in the present document as plug) consisted of a well section with cemented casing (Portland), constructed on purpose to allow for fluid circulation in a "microannulus". Results show that further evaluation and development of the concept of using tracers as an early warning system for permanent P&A is necessary. However, of the 8 tested tracers, 4 exhibit an ideal or close to ideal flooding behavior in the microannulus system that open the doors to such an application. Results also suggest that tracer tests using conventional inter-well water tracers can be devised to assess the quality of both borehole and casing cementing in conventional well-completion operations.
Reservoir stimulation with high anisotropy presents a challenge that various diversion techniques can address, including relative permeability modifiers (RPMs), nitrogen, and ball sealers. In vuggy carbonate reservoirs with high-permeability contrast, these diversion techniques often lose effectiveness, which makes mechanical isolation the preferred approach. Coiled tubing (CT) inflatable packers (IPs) have been widely used as one of the principal methods for mechanical isolation. However, their main limitations include setting depth accuracy, single-set capability, permanent deformation of the packer element, and restricted flow path options. The first global multi-set application of a fully electric inflatable packer (e-IP) deployed on CT is presented. The e-IP uses a 4-mm cable (five fiber optics plus a copper conductor) and downhole sensors to ensure precise placement of the element in a narrow area. The operation involved two CT runs. The first run used a high-efficiency jetting nozzle for casing conditioning and included a modular- sensing bottomhole assembly (MSBHA) to validate downhole conditions for the next run. After the downhole pressure was confirmed, final adjustments were made to the e-IP based on the maximum differential pressure and the ideal inflation pressure of the element for the next run. The second run deployed the e-IP bottomhole assembly (BHA) to conduct the acid stimulation. This assembly included the MSBHA, which used a gamma ray (GR) and casing collar locator (CCL) for depth correlation with a downhole pressure sensor to measure inflation pressure and calculate delta pressure (DP) in the tool, and to track the formation response to the acid. Weight on bit (WOB) confirmed that the packer anchored and monitored any abnormal behavior of the element throughout treatment. The e-IP features a unique running tool that provides access to and switches between different flow paths after the packer is set. The available flow options include: Above the packer: pump through the CT to spearhead acid into tight reservoirsBelow the packer: pump through the CTAbove the packer: pump down the annulus The real-time hybrid coiled tubing (RTHCT) system, equipped with an ultracompact MSBHA [pressure (P), temperature (T), CCL, GR, WOB, torque, inclination, tool face, and vibration] and an e-IP, exhibited stellar performance as a mechanical diversion method in high- permeability contrast reservoirs. The system executed three successful set/unset cycles in a single run. One of the setting cycles which was not initially planned at the start of the operation but was implemented based on real-time diagnostics provided by the MSBHA, demonstrating the flexibility and multi-set capability of the e-IP. The multi-set capability, combined with a diagnostic suite of sensors, reduces the number of runs and operational time required for accurate treatment placement. In operational environments where uncertainty is inevitable, the real-time decision-making capability of this tool combination enables appropriate actions during a single trip; therefore, time and total operational costs can be reduced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.