On-chip mass spectrometric analysis in non-polar solvents by liquid beam infrared matrix-assisted laser dispersion/ionization

Abstract: By the on-chip integration of a droplet generator in front of an emitter tip, droplets of non-polar solvents are generated in a free jet of an aqueous matrix. When an IR laser irradiates this free liquid jet consisting of water as the continuous phase and the non-polar solvent as the dispersed droplet phase, the solutes in the droplets are ionized. This ionization at atmospheric pressure enables the mass spectrometric analysis of non-polar compounds with the aid of a surrounding aqueous matrix that absorbs IR … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 84 publications
0
3
0
Order By: Relevance
“…Fluorescence detection is usually the method of choice due to the ease with which fluorescence data can be obtained from microscale channel layouts . Electrochemistry also offers tools that are amenable to component miniaturization, but like fluorescence detection, it suffers from a lack of universality in addition to difficulty in decoupling high voltage detection electronics responsible for driving flow. , Neither of these sensing techniques can match the selectivity and sensitivity of MS, which offers a near universal approach to detection of small molecules. , Samples most commonly ionized by a “soft” ionization method such as electrospray ionization (ESI) are identified with minimal molecular fragmentation based on mass-to-charge ratio . Spectral methods are typically combined with chromatographic methods to obtain nearly pure fractions of chemical components from crude samples .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescence detection is usually the method of choice due to the ease with which fluorescence data can be obtained from microscale channel layouts . Electrochemistry also offers tools that are amenable to component miniaturization, but like fluorescence detection, it suffers from a lack of universality in addition to difficulty in decoupling high voltage detection electronics responsible for driving flow. , Neither of these sensing techniques can match the selectivity and sensitivity of MS, which offers a near universal approach to detection of small molecules. , Samples most commonly ionized by a “soft” ionization method such as electrospray ionization (ESI) are identified with minimal molecular fragmentation based on mass-to-charge ratio . Spectral methods are typically combined with chromatographic methods to obtain nearly pure fractions of chemical components from crude samples .…”
Section: Discussionmentioning
confidence: 99%
“…57,58 Neither of these sensing techniques can match the selectivity and sensitivity of MS, which offers a near universal approach to detection of small molecules. 59,60 Samples most commonly ionized by a "soft" ionization method such as electrospray ionization (ESI) 61 are identified with minimal molecular fragmentation based on mass-to-charge ratio. 62 Spectral methods are typically combined with chromatographic methods to obtain nearly pure fractions of chemical components from crude samples.…”
Section: Discussionmentioning
confidence: 99%
“…However, ESI-MS analyses of compounds in non-polar, oil-like solvents are challenging. There is unfortunately still no sufficient method to investigate chemical processes in two immiscible phases on a single-droplet level by ESI-MS [25]. In the classical macroscopic laboratory, extraction methods such as separating funnels are often used to convert reaction mixtures from non-polar organic solvents into ESI-MS compatible solutions.…”
Section: Introductionmentioning
confidence: 99%