On-column radiometric detector for capillary isotachophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

1989
1989
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 22 publications
0
7
0
Order By: Relevance
“…Radioisotope detection of 32P, 14C, and "Tc has previously been reported by Kaniansky et al for isotachophoresis (7,20).…”
mentioning
confidence: 67%
See 1 more Smart Citation
“…Radioisotope detection of 32P, 14C, and "Tc has previously been reported by Kaniansky et al for isotachophoresis (7,20).…”
mentioning
confidence: 67%
“…Equation 2suggests that the number of counts measured (the detector sensitivity) over a sample peak may be increased by lengthening the residence time of the sample in the detection volume. This is equivalent to increasing the counting time on a liquid scintillation counter and this concept has been recognized in both radio HPLC applications (see, for example, ref 15) and radioisotope detection in isotachophoresis (7,20). In capillary electrophoresis, the velocity of a sample zone may be reduced and its residence time increased by simply reducing the applied potential as the zone passes through the detection volume.…”
Section: Resultsmentioning
confidence: 99%
“…When a neuron is grown in an 3'S-methionine rich culturing media, the newly synthesized methionine-containing peptides will be radiolabeled. While several radionuclide detection systems have been described for CE [ 18,191 and isotachophoresis [20,21], these implementations do not work well for 35S because the beta particles lack sufficient energy to penetrate the capillary wall and reach the detector. Consequently, previous approaches lack the required sensitivity.…”
Section: Radionuclide Detectionmentioning
confidence: 98%
“…While there are numerous examples of MCE employed for pharmaceutical analysis [ 73 , 76 ], there have been very few examples of CE methods, and no examples of MCE methods, applied to the analysis of radiopharmaceuticals. Separation and detection of 99m Tc-labeled SPECT compounds has been performed with capillary zone electrophoresis and isotachophoresis [ 77 , 78 , 79 , 80 , 81 ], and use of CE has been suggested for analysis of PET tracers in a patent application [ 30 ]. Recently, using the PET tracers [ 18 F]FLT and [ 18 F]FAC as model systems, our group explored the feasibility of using micellar electrokinetic chromatography (MEKC) to separate neutral tracers from neutral impurities, and showed comparable separation and limit of detection as HPLC/UV [ 82 ].…”
Section: Miniaturization Of Quality Control Testsmentioning
confidence: 99%