2016
DOI: 10.1016/j.ijepes.2016.02.008
|View full text |Cite
|
Sign up to set email alerts
|

On design and implementation of three phase three level shunt active power filter for harmonic reduction using synchronous reference frame theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(21 citation statements)
references
References 10 publications
0
21
0
Order By: Relevance
“…For this, a hysteresis band current controller is employed. Moreover, a DC bus controller is required to compensate power losses and to regulate the DC voltage in order to keep it in its set value [6]. For that, we use a PI controller with the parameters presented in the Appendix.…”
Section: Control Strategymentioning
confidence: 99%
See 1 more Smart Citation
“…For this, a hysteresis band current controller is employed. Moreover, a DC bus controller is required to compensate power losses and to regulate the DC voltage in order to keep it in its set value [6]. For that, we use a PI controller with the parameters presented in the Appendix.…”
Section: Control Strategymentioning
confidence: 99%
“…To overcome these limitations, active power filters with various forms (series, shunt, and hybrid) were proposed. The harmonic mitigation capability of the Shunt Active Power Filter (SAPF), which is the commonly used form [6], is mainly determined by the distortions detection method, as well as the compensation control strategy [7].…”
Section: Introductionmentioning
confidence: 99%
“…In the SRF theory [15][16][17][18], the three-phase instantaneous nonlinear load currents (i La , i Lb and i Lc ) are transformed from the a-b-c coordinates into α-β coordinates by the following equation;…”
Section: Synchronous Reference Frame Theorymentioning
confidence: 99%
“…A paper by Kakoli Bhattacharjee says that the synchronous reference frame method (SRF) is based on the fact that harmonics change their frequency in a rotating reference frame, and so they are better isolated with high pass filters [7]. Sundaram and Venugopal used synchronous reference frame algorithm to implement a three phase three level SAPF on an embedded platform [8]. A modified harmonic and reactive current detection method based on SRF theory for three-phase four-wire SAPF is proposed under distorted supply voltages condition in a paper by Xiangshun et al [9].…”
Section: Shunt Active Power Filter (Sapf)mentioning
confidence: 99%