2007
DOI: 10.1016/j.jhazmat.2006.09.051
|View full text |Cite
|
Sign up to set email alerts
|

On-line arsenic co-precipitation on ethyl vinyl acetate turning-packed mini-column followed by hydride generation-ICP OES determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
39
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 56 publications
(39 citation statements)
references
References 31 publications
0
39
0
Order By: Relevance
“…The total arsenic concentration in a leaching solution was measured by an iCAP 6300 inductance-coupling plasma (ICP) emission spectrometer (Thermo Fisher Scientific; USA), following the procedure as described in previous studies (Gil et al 2007;Lopes et al 2009). Different forms of arsenic concentration in the solution after leaching were measured by a liquid chromatography-atomic fluorescence spectrometer (LC-AFS) model 9700 (Beijing Haiguang Instrument Co., Ltd.).…”
Section: Analysis Methodsmentioning
confidence: 99%
“…The total arsenic concentration in a leaching solution was measured by an iCAP 6300 inductance-coupling plasma (ICP) emission spectrometer (Thermo Fisher Scientific; USA), following the procedure as described in previous studies (Gil et al 2007;Lopes et al 2009). Different forms of arsenic concentration in the solution after leaching were measured by a liquid chromatography-atomic fluorescence spectrometer (LC-AFS) model 9700 (Beijing Haiguang Instrument Co., Ltd.).…”
Section: Analysis Methodsmentioning
confidence: 99%
“…In general, Optical Emission Spectroscopy (OES) can assist the analysis of environmental trace pollutants, such as heavy metals, trace materials and air toxics. OES allows low detection limits and has found wide applications in the determination of trace levels of arsenic combined with atomic absorption spectrometry (Näykki, et al, 2001), atomic fluorescence spectrometry (AFS) (Leal et al, 2004) or coupled with optical emission spectroscopy-inductively coupled plasma (ICP-OES) (Anthemidis et al, 2006;Gil et al, 2007). Moreover, correlation between the OES plasma composition and the diamond film properties was also studied by Vandevelde et al (1999) during microwave PA-CVD with nitrogen addition.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, if ignoring the Raman shift (that is, ω e ∼ω s , where ω e , ω s is frequency of the excitation light and Raman scattering light, respectively), the SERS EF due to the EM effect can be approximated [6] In experiments, the SERS EF can be estimated by [7] where I SERS , I Norm is the intensity of a specific characteristic peak in the SERS and normal Raman measurements, respectively; N SERS , N Norm is the number of molecules contributing to the Raman signal in the SERS and normal Raman measurements, respectively.…”
mentioning
confidence: 99%
“…49,50 For example, when the gap size decreases from 5.5 nm to 1 nm, the SERS enhancement will improve from ∼10 6 to 10 11 . [51][52][53][54][55] Consequently, when analyte molecules are adsorbed on "hot spots", SERS signals of the analyte can be enhanced by 10 6 or even up to 10 11 . 51,56,57 As a result, even a single molecule can be detected by SERS sensor.…”
mentioning
confidence: 99%