1985
DOI: 10.1109/mper.1985.5528455
|View full text |Cite
|
Sign up to set email alerts
|

On-Line Computation of Phase Shifter Distribution Factors and Lineload Alleviation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2004
2004
2012
2012

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…The optimal power flow (OPF) with phase shifter is a good choice. In order to retain the symmetry of Y bus, the injection model of phase shifter used in [23][24] is adopted in this paper. The proposed approach is tested on an IEEE 30-bus test system with a phase shifters located in a transmission line.…”
Section: International Journal Of Computer Applications (0975 -8887) mentioning
confidence: 99%
See 1 more Smart Citation
“…The optimal power flow (OPF) with phase shifter is a good choice. In order to retain the symmetry of Y bus, the injection model of phase shifter used in [23][24] is adopted in this paper. The proposed approach is tested on an IEEE 30-bus test system with a phase shifters located in a transmission line.…”
Section: International Journal Of Computer Applications (0975 -8887) mentioning
confidence: 99%
“…It provides an economically and technically attractive solution to power system security problem by use of some efficient controls, such as controllable series capacitors, phase shifters, and load shedding, etc., [2]- [6]. Several techniques have been proposed in the past for the adjustment of phase shifter or the adjustment of controllable series capacitor to alleviate line overloads [5], [6].…”
Section: Introductionmentioning
confidence: 99%
“…In [3,4], the simplified phase shifter injection models (only active power injections) are given. In [5,6,7], the extension of this model are given i.e. the reactive injections are taken into account, but in all of above mentioned approaches, the conductance of elements with PST are neglected.…”
Section: Phase Shifter Injection Modelmentioning
confidence: 99%
“…For some early considerations interested readers are referred to [5][6][7][8][9] and for recent ones to [10][11][12][13]. All these considerations could be roughly classified as optimization [8,13] and non-optimization (direct) based [5][6][7][9][10][11][12]. Optimization based methods (particularly optimal power flow) are arguably more accurate but computationally expensive and time consuming [11].…”
Section: Introductionmentioning
confidence: 99%