1998
DOI: 10.1021/ac980611y
|View full text |Cite
|
Sign up to set email alerts
|

On-Line Emission Analysis of Polycyclic Aromatic Hydrocarbons down to pptv Concentration Levels in the Flue Gas of an Incineration Pilot Plant with a Mobile Resonance-Enhanced Multiphoton Ionization Time-of-Flight Mass Spectrometer

Abstract: A newly developed, mobile laser mass spectrometer (resonance-enhanced multiphoton ionization - time-of-flight mass spectrometer, REMPI-TOFMS) was applied to on-line measurements at a waste incineration pilot plant. REMPI-TOFMS combines the optical selectivity of resonance-enhanced multiphoton ionization with a time-of-flight mass analysis to give a two-dimensional analytical method. Special care was taken to build up a sampling and inlet system suitable for on-line measurements of large, semivolatile polycycli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
184
0

Year Published

1999
1999
2017
2017

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 157 publications
(186 citation statements)
references
References 41 publications
2
184
0
Order By: Relevance
“…Figure 1 shows an expanded view of the data in the form of a two-dimension display in the region of tetrachlorodibenzo-p-dioxins (tetraCDDs) and tetrachlorodibenzofurans (tetraCDFs), measured using the picosecond laser. All native 12 C-congeners of tetraCDD/Fs, in addition to the 13 C-congeners that had been added to the sample solution as internal standards, could be clearly observed, and the intensity distributions of the isotope peaks were identical to those calculated from the natural abundance of the chlorine atom. Thus, tetraCDD/Fs as well as other CDD/Fs congeners can easily be identified using two-dimensional display data.…”
Section: Dxnsmentioning
confidence: 69%
See 1 more Smart Citation
“…Figure 1 shows an expanded view of the data in the form of a two-dimension display in the region of tetrachlorodibenzo-p-dioxins (tetraCDDs) and tetrachlorodibenzofurans (tetraCDFs), measured using the picosecond laser. All native 12 C-congeners of tetraCDD/Fs, in addition to the 13 C-congeners that had been added to the sample solution as internal standards, could be clearly observed, and the intensity distributions of the isotope peaks were identical to those calculated from the natural abundance of the chlorine atom. Thus, tetraCDD/Fs as well as other CDD/Fs congeners can easily be identified using two-dimensional display data.…”
Section: Dxnsmentioning
confidence: 69%
“…[11][12][13][14][15][16][17][18][19][20][21] The MPI technique reduces undesirable interfering signals and enables the acquisition of a mass spectrum with fewer fragment peaks.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, Zimmermann et al developed a capillary-based effusive inlet system, in which the tip of the capillary was positioned in the center of the two acceleration plates of the first stage of the ion source. 35 Using this system, researchers achieved a higher overlap of the sample and the ionization laser. Subsequently, a capillary-based supersonic molecular beam nozzle was developed by restricting the top of the capillary, resulting in an increased sensitivity and selectivity.…”
Section: ·1 Sample Inlet Systemmentioning
confidence: 99%
“…[1][2][3] This method has advantages that include selectivity, rapidity, and robustness. 4,5 Therefore, LI-TOFMS is used extensively in the measurement of complex environmental samples, [6][7][8][9][10][11] biological molecules, 12 bioactive substances, 13 and polymers. 14,15 Emulsions are heterogeneous systems where one liquid is dispersed into another as droplets.…”
Section: Introductionmentioning
confidence: 99%