2002
DOI: 10.1021/ac026187p
|View full text |Cite
|
Sign up to set email alerts
|

On-Line Hyphenation of Capillary Isoelectric Focusing and Capillary Gel Electrophoresis by a Dialysis Interface

Abstract: An on-line two-dimensional (2D) capillary electrophoresis (CE) system consisting of capillary isoelectric focusing (CIEF) and capillary gel electrophoresis (CGE) was introduced. To validate this 2D system, a dialysis interface was developed by mounting a hollow fiber on a methacrylate resin plate to hyphenate the two CE modes. The two dimensions of capillary shared a cathode fixated into a reservoir in the methacrylate plate; thus, with three electrodes and only one high-voltage source, a 2D CE framework was s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
74
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 78 publications
(74 citation statements)
references
References 52 publications
0
74
0
Order By: Relevance
“…Micellar electrokinetic chromatography has been coupled to CZE 10,11 or capillary gel electrophoresis (CGE). 12 In both cases, high-resolution separations have been obtained in a reduced period of time. However, in the context of developing two-dimensional separations, CIEF, due to its high loading capacity, resolution, and concentrating power, appears as the most suitable first dimension.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Micellar electrokinetic chromatography has been coupled to CZE 10,11 or capillary gel electrophoresis (CGE). 12 In both cases, high-resolution separations have been obtained in a reduced period of time. However, in the context of developing two-dimensional separations, CIEF, due to its high loading capacity, resolution, and concentrating power, appears as the most suitable first dimension.…”
mentioning
confidence: 99%
“…However, in the context of developing two-dimensional separations, CIEF, due to its high loading capacity, resolution, and concentrating power, appears as the most suitable first dimension. So far, CIEF has been coupled to CGE 12 and to CZE. 10 A very accomplished work is certainly the one published by Mohan et al 13,14 In these studies, a microdialysis junction has been employed to hyphen CIEF and CZE.…”
mentioning
confidence: 99%
“…Zhang and co-workers combined CIEF with capillary gel eletrophoresis (CGE) [38], by mounting a hollow fiber on a methacrylate resin plate (Fig. 1).…”
Section: Ce-cementioning
confidence: 99%
“…Capillaries (50-lm ID, 375-lm OD) from Ruiyang Chromatographic Device Co. Ltd (Yongnian, Hebei, China) were coated with polyacrylamide as described previously [16]. In brief, after being cleaned and dried a capillary was filled with a solution of c-MAPS (50% v/v in methanol) and kept at room temperature with both the ends sealed by silicone septa.…”
Section: Reagents and Instrumentationmentioning
confidence: 99%