Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95
DOI: 10.1109/imtc.1995.515406
|View full text |Cite
|
Sign up to set email alerts
|

On-line measurement of equivalent parameters of distribution system and its load for harmonic frequencies

Abstract: An on-line measurement of equivalent parameters of a distribution system and a harmonic generating load is discussed in the paper. Four parameters are the subjects of the measurement: the distribution system and the load complex impedances, the complex rms (crms) values J, of the load generated current j harmonics and the crms values E, of the distribution system internal voltage e harmonics.The method discussed is based on measurements performed in two states of the system, before and after disturbing it by a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
3

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(17 citation statements)
references
References 3 publications
0
14
0
3
Order By: Relevance
“…From the model shown in Figure , the following relationship can be derived for a given frequency f between utility side parameters, that is, complex background harmonic voltage E and HI Z on one hand, and PCC complex harmonic voltage V and current I on the other : V=EIZ. …”
Section: Problem Formulationmentioning
confidence: 99%
“…From the model shown in Figure , the following relationship can be derived for a given frequency f between utility side parameters, that is, complex background harmonic voltage E and HI Z on one hand, and PCC complex harmonic voltage V and current I on the other : V=EIZ. …”
Section: Problem Formulationmentioning
confidence: 99%
“…They have, however, more disadvantages: they are passive, so identification can be done only on systemexisting harmonics, and it is of a poor quality [7]. The large capacitor banks should be precharged and switched on the top of line voltage, and switched off with the zero current -such switching needs additional hardware.…”
Section: Problemsmentioning
confidence: 99%
“…The "black box" power system description is necessary if there is a lack or limited knowledge on the power grid structure and its loads. In such situations the impedance identification / measurement experiment is a principal source of the information on the grid [1], [2], [5]. Impedance and voltage observations in the PCC deliver the linear model of the grid which has plenty of useful implementations [5], [6], [7].…”
Section: Introductionmentioning