2011
DOI: 10.1016/j.biortech.2011.03.111
|View full text |Cite
|
Sign up to set email alerts
|

On-line monitoring of the transesterification reaction between triglycerides and ethanol using near infrared spectroscopy combined with gas chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
41
0
2

Year Published

2012
2012
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(44 citation statements)
references
References 36 publications
1
41
0
2
Order By: Relevance
“…Comparatively to the batch reaction mixtures analyses performed in previous work [34], both standard errors RMSEC and RMSEP increased because the NIR spectra obtained by the reflection or the transflectance probe and measured through PFA tube show more noise than the NIR spectra acquired with the transflectance optical probe directly in the reactor. Indeed, the optical beam is altered when passing through the PFA tube due to dispersion.…”
Section: Partial Least Squares Regressions (Pls)mentioning
confidence: 65%
See 2 more Smart Citations
“…Comparatively to the batch reaction mixtures analyses performed in previous work [34], both standard errors RMSEC and RMSEP increased because the NIR spectra obtained by the reflection or the transflectance probe and measured through PFA tube show more noise than the NIR spectra acquired with the transflectance optical probe directly in the reactor. Indeed, the optical beam is altered when passing through the PFA tube due to dispersion.…”
Section: Partial Least Squares Regressions (Pls)mentioning
confidence: 65%
“…In order to remove small inter-microreactor differences due to uncontrolled variation sources, data pre-processing methods were applied to the spectra, such as baseline correction, Savitzky-Golay smoothing, first or second derivative, mean centering, The reaction was previously performed in a 1 L-batch reactor for several ethanol to oil molar ratios at 70 °C [34]. The mechanical stirring speed was 750 rpm in order to have a satisfactory mixing in the batch reactor.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurements provide valuable information about the operating conditions and simultaneously give an estimate for critical variables by monitoring the state of a process and verifying that performance is optimal. There are methods to monitor the progress of the reaction, such as gas and liquid chromatography [9][10][11][12], Fourier transform infrared (FTIR), near-infrared (NIR), and nuclear magnetic resonance (NMR) spectroscopy methods [10,[12][13][14][15][16][17], measurement of refractive index [18], and viscosity [19]. Most of these methods require samples to be taken and offline analyses to be performed which include a pre-treatment of the sample.…”
Section: Introductionmentioning
confidence: 99%
“…An instrument that is able to perform the process accurately, ranging from chemical reactions (production) to quality control (final product), is necessary. Due to the automation of processes, in-line measurements are increasingly being studied to ensure that the product is in conformity to technical requirements [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%