“…Moving average smoothing was applied next (n~5) and finally the mass flow was computed from each point in the chromatogram using the measured ratio as R m in eqn. (9). Fig.…”
Section: On-line Isotope Dilution Analysis For Fe Cu and Zn In Human ...mentioning
confidence: 99%
“…Moving average smoothing was applied next (n~5) and finally the mass flow was computed from each point in the chromatogram using the measured ratio as R m in eqn. (9). Fig.…”
Section: On-line Isotope Dilution Analysis For Fe Cu and Zn In Human ...mentioning
confidence: 99%
“…159 This is offset by a higher background noise, reducing the gain in detection limit to a factor of 2-10. 171,172 4.2.1 Atomic absorption spectrometry (AAS). Post-column spectrophotometric reaction with Pyrocatechol Violet was used for the detection of Al in SE HPLC of an extract of a tea sample.…”
Section: Element-specific Detection In Hplcmentioning
confidence: 99%
“…68,158,162,[171][172][173][174][175][176][177][178][179][180] They can be decreased by the use of an ultrasonic nebulizer 68 or a direct injection nebulizer (in absolute terms). 68,158,162,[171][172][173][174][175][176][177][178][179][180] They can be decreased by the use of an ultrasonic nebulizer 68 or a direct injection nebulizer (in absolute terms).…”
Section: Inductively Coupled Plasma Atomic Emission Spectrometry (Icpmentioning
confidence: 99%
“…Here, we employed native separation using size exclusion chromatography (SEC) hyphenated to ICP-MS for detection of metal cofactors according to molecular weight of the eluting biomolecules. Coupling SEC to elemental detection itself is not a new analytical technique; the first featured examples, reported in the 1980s, used atomic absorption 13 and atomic emission spectrometry 14 to detect trace metals in various biological fluids.…”
Section: Introductionmentioning
confidence: 99%
“…Here, we employed native separation using size exclusion chromatography (SEC) hyphenated to ICP-MS for detection of metal cofactors according to molecular weight of the eluting biomolecules. Coupling SEC to elemental detection itself is not a new analytical technique; the first featured examples, reported in the 1980s, used atomic absorption 13 and atomic emission spectrometry 14 to detect trace metals in various biological fluids. Since then, a number of examples of SEC hyphenated to mass specific detection have been used to study trace metals in a variety of physiological and disease states, including rat serum, 15 cancerous human thyroid tissue, 16 murine neurological tissue 17 and platinum-treated human blood products 18 to name just a few.…”
Section: Introductionmentioning
confidence: 99%