2002
DOI: 10.1016/s0003-2670(02)00089-2
|View full text |Cite
|
Sign up to set email alerts
|

On-line simultaneous determination of S- and R-perindopril using amperometric biosensors as detectors in flow systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2004
2004
2015
2015

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…Generally, the transduction system is based on monitoring hydrogen peroxide electrooxidation. Taking advantage of the high selectivity of these enzymes, simultaneous detection of S-and R-captopril [77] or S-and R-perindopril [78] has been possible using flow injection [68] analysis with sequential injection at a rate of more than 30 samples per hour. Application to pharmaceuticals has been realized.…”
Section: Stereoselective Biosensorsmentioning
confidence: 99%
“…Generally, the transduction system is based on monitoring hydrogen peroxide electrooxidation. Taking advantage of the high selectivity of these enzymes, simultaneous detection of S-and R-captopril [77] or S-and R-perindopril [78] has been possible using flow injection [68] analysis with sequential injection at a rate of more than 30 samples per hour. Application to pharmaceuticals has been realized.…”
Section: Stereoselective Biosensorsmentioning
confidence: 99%
“…In this work, they utilised an enantioselective membrane electrode based on maltodextrin for the potentiometric detection of S-captopril and the amperiometric sensor previously described for the determination of R-captopril. The two amperiometric detectors previously described (based on d-and l-amino acid oxidase) were also applied in the simultaneous determination of S-and R-perindopril [131]. These two detectors were incorporated in two flow analysis systems (FIA and SIA).…”
Section: Electrochemistrymentioning
confidence: 99%
“…Membrane technologies (potentiometric sensors with polymer membranes containing a selector [6,[28][29][30]), classical biosensors (determination of optically active enzyme substrates [31][32][33][34][35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50]), and the whole range of techniques for the chemical modification of metal and graphite electrodes can be used for this purpose. Membrane technologies (potentiometric sensors with polymer membranes containing a selector [6,[28][29][30]), classical biosensors (determination of optically active enzyme substrates [31][32][33][34][35][36][37][38][39][40][41][42][43][44][45][46][47][48][49]…”
Section: Characteristics Of Selectorsmentioning
confidence: 99%