2023
DOI: 10.1016/j.geoderma.2023.116509
|View full text |Cite
|
Sign up to set email alerts
|

On measuring methods and influencing factors of air permeability of soils: An overview and a preliminary database

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 134 publications
0
2
0
Order By: Relevance
“…In this study, the variation in soil surface temperature explained the variation in CH 4 flux well (R2=0.52) (Figure 5). With seasonal changes, the decrease in soil moisture caused by warming leaded to increased soil permeability (Juc´a and Maciel, 2006;Lu et al, 2023), promoting the diffusion of CH 4 from the atmosphere into the deep soil and thereby enhancing CH 4 absorption. In a typical steppe in semiarid areas, the increase in water may not reach the threshold level that affects methanotrophs, hence no significant correlation between CH 4 flux and soil surface moisture was noted.…”
Section: Relationships Between Ch 4 and Environmental Factorsmentioning
confidence: 99%
“…In this study, the variation in soil surface temperature explained the variation in CH 4 flux well (R2=0.52) (Figure 5). With seasonal changes, the decrease in soil moisture caused by warming leaded to increased soil permeability (Juc´a and Maciel, 2006;Lu et al, 2023), promoting the diffusion of CH 4 from the atmosphere into the deep soil and thereby enhancing CH 4 absorption. In a typical steppe in semiarid areas, the increase in water may not reach the threshold level that affects methanotrophs, hence no significant correlation between CH 4 flux and soil surface moisture was noted.…”
Section: Relationships Between Ch 4 and Environmental Factorsmentioning
confidence: 99%
“…Although it can measure the volume change of soil samples using a flexible wall cell and apply confining pressure, it still does not solve the problem of gas pressure fluctuation (15 kPa) [30][31][32][33][34]. Compared with the flexible wall permeameter, although the triaxial permeameter does not solve the problem of gas pressure fluctuation (3.2 kPa), it is widely used due to its high testing accuracy and the ability to apply confining pressure and principal pressure [35][36][37][38][39]. By developing a gas supply device with two Mariotte bottles [40] as the core component, Chen et al (2021) effectively addressed the gas pressure fluctuation under low pressures (20 kPa), simplified the measurement of gas flow velocity, and improved the gas pressure supply accuracy to 0.01 kPa [24].…”
Section: Introductionmentioning
confidence: 99%