2016
DOI: 10.1016/j.cej.2016.01.072
|View full text |Cite
|
Sign up to set email alerts
|

On the adsorbate restructuring induced hysteresis of simple gas adsorption in slit micropores

Abstract: Simulations of adsorption isotherms for simple gases in homogeneous slit pores with two open ends often show hysteresis, between condensation and evaporation branches. The hysteresis may result either, from the difference in the curvature of the interface separating the adsorbed and gas phases, or from molecular restructuring when the adsorbate is densely packed. The order-disorder transition that occurs in the second case, has also been observed experimentally for adsorption on a graphite surface, and is supp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 44 publications
0
4
0
Order By: Relevance
“…Low-permeability heterogeneous reservoirs are mostly developed with micro-nano-scale pore throats, which generate high capillary pressure and lead to adsorption hysteresis effect. This adsorption hysteresis effect obviously affects the critical properties and phase behavior of fluids [14][15][16]. The critical shift parameter is measured using the corresponding correlation proposed by Zarragoicoechea et al [17]:…”
Section: Modified Equation Of Statementioning
confidence: 99%
“…Low-permeability heterogeneous reservoirs are mostly developed with micro-nano-scale pore throats, which generate high capillary pressure and lead to adsorption hysteresis effect. This adsorption hysteresis effect obviously affects the critical properties and phase behavior of fluids [14][15][16]. The critical shift parameter is measured using the corresponding correlation proposed by Zarragoicoechea et al [17]:…”
Section: Modified Equation Of Statementioning
confidence: 99%
“…The numerous slit-type and round-type pore structures below 10 nm diameter were found on the surface of coal (lignite from the Xilinhot region of Inner Mongolia, China) by scanning electron microscopy (SEM) techniques, as shown in Figure 1 a-c. When studying the coal pore structure on gas adsorption characteristics, the graphite slit model was often used [13,31,35,37,51], as shown in Figure 1 d. As in Figure 1(c), the default distance between graphite slit models in the molecular simulation software was H, but the distance between the pore walls of coal in the actual case was H`, the conversion equation between H and H` was as follows.…”
Section: Modelsmentioning
confidence: 99%
“…At the same time, coal is a cross-linked molecule with high molecular weight [7]. In order to simplify the molecular structure of coal, scholars mostly adopted the graphite slit model with regular arrangement of carbon atoms to study the effect of coal pore structure on gas adsorption, and the results obtained by molecular simulation showed good similarity with the experimental results [35][36][37].…”
mentioning
confidence: 93%
“…In a closed-end pore, the isotherms were found to be reversible for all pore sizes studied, because the closed end acts as a nucleation site for the liquid condensate to form. There is a hysteresis loop associated with restructuring of the condensate in both the open and closed end pores of 1.5nm width over a pressure range above the condensation pressure 149 . To elucidate the mechanism of the restructuring we present, in Figure 6.7, the local density distributions and snapshots just before and just after Points A and B in Figure 6 5.30kJ/mol, respectively.…”
Section: Effects Of Pore Sizementioning
confidence: 99%