2017
DOI: 10.1016/j.cemconres.2017.05.014
|View full text |Cite
|
Sign up to set email alerts
|

On the measurement of evolution of structural build-up of cement paste with time by static yield stress test vs. small amplitude oscillatory shear test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
70
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 220 publications
(72 citation statements)
references
References 15 publications
1
70
0
1
Order By: Relevance
“…The critical strain is typically of an order of 10 −4 [31,37,[41][42][43]. In the LVE domain, the evolution of G' with time can serve as a measurement of structural build-up [31,37]. However, exceeding the critical strain induces non-linear visco-elastic behaviour, significantly complicating the analysis [40].…”
Section: Visco-elasticity 34mentioning
confidence: 99%
See 3 more Smart Citations
“…The critical strain is typically of an order of 10 −4 [31,37,[41][42][43]. In the LVE domain, the evolution of G' with time can serve as a measurement of structural build-up [31,37]. However, exceeding the critical strain induces non-linear visco-elastic behaviour, significantly complicating the analysis [40].…”
Section: Visco-elasticity 34mentioning
confidence: 99%
“…Stress or strain amplitude sweeps are generally used to determine the critical strain or stress of cement paste, which generally corresponds to the end of the LVE or to the onset of flow. The critical strain is typically of an order of 10 −4 [31,37,[41][42][43]. In the LVE domain, the evolution of G' with time can serve as a measurement of structural build-up [31,37].…”
Section: Visco-elasticity 34mentioning
confidence: 99%
See 2 more Smart Citations
“…1983 m. Tattersall ir Banfill (1983) įvedė "negrįžtamojo struktūrinio suardymo" terminą, pažymėdami faktą, kad cementiniai mišiniai pasižymi nuo šlyties priklausoma reologine elgsena. Yuan et al (2017), Yahia et al (2016), Lecompte ir Perrot (2017) ir Jiao et al (2017) nustatė, kad esant didelei šlyčiai (maišant mišinį betono maišyklėje), cementinių mišinių dinaminiai ribiniai šlyties įtempiai ne visiškai atsistato iki prieš tai buvusių dėl cemento hidratacijos poveikio. Tačiau "likutiniai" statiniai ribiniai šlyties įtempiai susiję su susiformavusia mišinio mikrostruktūra, kuri gali būti suardoma veikiant šlyčiai ir atsistato ramybės būsenos metu (Yahia et al, 2016;Jiao et al, 2017;Marchesini et al, 2019).…”
Section: Cementinių Mišinių Tiksotropiškumasunclassified