2019
DOI: 10.1016/j.cherd.2019.06.013
|View full text |Cite
|
Sign up to set email alerts
|

On the reliability of lab-scale experiments for the determination of membrane specific flux measurements in organic solvent nanofiltration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…Each membrane cell contained a membrane cutout from the same batch of the membrane material to be screened in order to perform an estimation of the mean and standard deviation for membrane flux and ion rejection. The membrane flux, as determined by small samples in lab-scale experiments, is well known to exhibit significant variations due to the inhomogeneity of the membrane material [58]. Retentate and permeate were continuously recycled to the feed vessel.…”
Section: Membrane Setupmentioning
confidence: 99%
“…Each membrane cell contained a membrane cutout from the same batch of the membrane material to be screened in order to perform an estimation of the mean and standard deviation for membrane flux and ion rejection. The membrane flux, as determined by small samples in lab-scale experiments, is well known to exhibit significant variations due to the inhomogeneity of the membrane material [58]. Retentate and permeate were continuously recycled to the feed vessel.…”
Section: Membrane Setupmentioning
confidence: 99%
“…Nevertheless, significant progress in the commercialization of large‐scale modules for OSN has been limited by the substantial difference between different nanofiltration membrane samples, together with the difference in membrane performance between industrial modules and lab‐scale tests. [ 303 ] Hence, all these hurdles must be carefully addressed to ensure the realization of the industrial application of large‐scale membrane modules for OSN in the near future.…”
Section: Conclusion and Future Perspectivesmentioning
confidence: 99%
“…The sample standard deviation for membrane screening data should be provided and it should be based on at least three independent replicates. 24 Replicates for long processes, in particular continuous operation, are not necessary given that the membrane screening proved the reliability of the membrane performance. New/prospective membrane materials cannot be used in an application if a similar performance to that reported in a previous paper cannot be obtained.…”
Section: Reliable Reports On the Characterization Of Membranesmentioning
confidence: 99%
“…Multiple measurements with different membrane coupons are indispensable because the variation in the flux of the same membrane material could be as high as 33% even under the same experimental conditions due to possible leakages and defects in the membrane material. 24 Despite the need for reliable estimates of uncertainty, around a quarter of the OSN papers surveyed provided performance data as individual data points (Fig. 5).…”
Section: Reliable Reports On the Characterization Of Membranesmentioning
confidence: 99%