The fundamental condition of the sufficient vibration-isolation is that all natural frequencies of a system are placed outside the interval of exciting frequencies. By the application of a gyroscopic stabilizer depend some natural frequencies on the gyroscope impulse moment. There is described how to reach the fundamental condition by the help of sufficient magnitude of gyroscopes impulse moment.