2019
DOI: 10.1097/hpc.0000000000000162
|View full text |Cite
|
Sign up to set email alerts
|

One-Hour High Sensitivity Troponin Testing: A Safe and Effective Triage Tool for the Emergency Department

Abstract: The latest European Society of Cardiology guideline on the management of acute coronary syndromes without persistent ST-elevation stipulates several acceptable pathways through which patients presenting with chest pain can be assessed for unstable coronary disease. This article reviews the data behind the “rule-in and rule-out algorithm,” which can exclude acute myocardial infarction within 1 hour of presentation through the use of fifth generation high-sensitivity troponin assays.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The report explained that these current measurements are now sufficiently sensitive that minor troponin concentration variations, such as a few ng/L, can be detected, allowing for a more accurate diagnosis [24,27,31,40,47,50,78]. Hence, an earlier risk stratification of AMI likelihood is now possible [27,31,35,40,78,89,92]. Thanks to these new assays, the delay between the two troponin measurements may be reduced to 1 hour [27,31,38,89,93]: the first measurement should be performed upon apatient's admission to the ED, the second being taken one hour later.…”
Section: Cardiac Troponinmentioning
confidence: 95%
See 4 more Smart Citations
“…The report explained that these current measurements are now sufficiently sensitive that minor troponin concentration variations, such as a few ng/L, can be detected, allowing for a more accurate diagnosis [24,27,31,40,47,50,78]. Hence, an earlier risk stratification of AMI likelihood is now possible [27,31,35,40,78,89,92]. Thanks to these new assays, the delay between the two troponin measurements may be reduced to 1 hour [27,31,38,89,93]: the first measurement should be performed upon apatient's admission to the ED, the second being taken one hour later.…”
Section: Cardiac Troponinmentioning
confidence: 95%
“…Since 2010, high-sensitivity troponin assays are available [88]. They allow a more rapid [35,38,49,78,89] and more accurate detection [27,31,35,38] compared to conventional assays, offering a reduction of the detection limit from µg/L to ng/L [27,37,47,50,89]. These highly-sensitive troponin measurements are very efficient at the first stage of the myocardial infarction because they allow the identification of early necrosis [29,50].…”
Section: Cardiac Troponinmentioning
confidence: 99%
See 3 more Smart Citations