2018
DOI: 10.1049/iet-epa.2017.0438
|View full text |Cite
|
Sign up to set email alerts
|

Online diagnostic method of open‐switch faults in PWM voltage source rectifier based on instantaneous AC current distortion

Abstract: The three-phase pulse-width modulating (PWM) voltage source rectifier (VSR) system is widely used because of its advantages in performance. Numerous studies show that power semiconductors are significant contributors to the overall failure rate of power converters. This study presents an online diagnosis method for a single open-switch fault of a three-phase PWM VSR, because existing research mainly focuses on fault diagnosis of inverters. The proposed method employs current distortion to diagnose faults in a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 33 publications
(41 reference statements)
0
24
0
Order By: Relevance
“…In practice, a power switch comprises two main parts: an insulated-gate bipolar transistor (IGBT) and a parallel freewheel diode (PFD). Power switch faults caused by gate drive failures easily lead to OCFs in the motor side converter (MSC) [22]. In this case, the PFD remains connected to the MSC, even though its parallel connected switch is open.…”
Section: B Fault Conditionsmentioning
confidence: 99%
“…In practice, a power switch comprises two main parts: an insulated-gate bipolar transistor (IGBT) and a parallel freewheel diode (PFD). Power switch faults caused by gate drive failures easily lead to OCFs in the motor side converter (MSC) [22]. In this case, the PFD remains connected to the MSC, even though its parallel connected switch is open.…”
Section: B Fault Conditionsmentioning
confidence: 99%
“…The detection and location technique based on the Park approach combined with polar coordinates. 20 The fault angle is calculated from Equations 16-18 as follows. 20…”
Section: Detection and Location The Open-circuit Fault Each Igbt Swmentioning
confidence: 99%
“…The fault current vector of each IGBT, expressed by the following equation 20 : According to Figure 5 it is possible to calculate the intervals of the faulty angles of each leg, the intervals of the faulty angles of each IGBT and the exact faulty angles of each IGBT.…”
Section: Detection and Location The Open-circuit Fault Each Igbt Swmentioning
confidence: 99%
“…Once fault occurs, the system runs under abnormal conditions or causes substantial economic losses. Hence, an efficient and accurate fault diagnosis approach is of the utmost to ensure the reliability and security of the PWM rectifiers [3].…”
Section: Introductionmentioning
confidence: 99%