Online Measurement Techniques for Determining Oil Circulation Rate

Abstract: Refrigeration and air-conditioning (AC) systems employ refrigerant as the working fluid; however, a portion of oil is discharged from the compressor as part of the compression process and also circulates through the system. This small amount of parasitic fluid causes heat transfer and pressure drop correlations that were developed for pure refrigerant flow to fail and needs to be determined for proper design of heat exchange equipment and connection piping. It is desired to be able to measure the small concent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…Summarizing, the steps of the procedure are the following: take a refrigerant sample and weight it, then the refrigerant in the sample is slowly evacuated letting it evaporate through a capillary tube, create vacuum in the sample cylinder, weight it again, clean the interior with acetone, let it evaporate… The described methodology results in accurate results when all the steps are rigorously followed but it is a time-consuming procedure with tedious steps which limits the number of tests that can viably be done. Additionally, it is needed a scale with great accuracy and resolution and, what it is more important, the sampling is invasive as it affects the overall quantity of oil and refrigerant in the studied system (Wujek et al, 2007).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Summarizing, the steps of the procedure are the following: take a refrigerant sample and weight it, then the refrigerant in the sample is slowly evacuated letting it evaporate through a capillary tube, create vacuum in the sample cylinder, weight it again, clean the interior with acetone, let it evaporate… The described methodology results in accurate results when all the steps are rigorously followed but it is a time-consuming procedure with tedious steps which limits the number of tests that can viably be done. Additionally, it is needed a scale with great accuracy and resolution and, what it is more important, the sampling is invasive as it affects the overall quantity of oil and refrigerant in the studied system (Wujek et al, 2007).…”
Section: Introductionmentioning
confidence: 99%
“…These methods are based in thermal conductivity (Wujek et al, 2007), dielectric constant (Hwang et al, 2008), high speed cameras (Xu and Hrnjak, 2017), UV absorption (Kutsuna et al, 1991), speed of sound (Lebreton et al, 2001) and refraction (Fukuta et al, 2006) among others. However, these techniques require high end and experimental equipment with specific calibrations for each test bench, refrigerant and lubricant.…”
Section: Introductionmentioning
confidence: 99%