“…Yet, this work does not explain how to obtain the synchronization angle and the effect of synchronization dynamics on the impedance measurement results. An oscillator that is synchronized to the grid voltage was adopted to generate the synchronization phase used for the impedance calculation [10], [11]. Applying the Fast Fourier Transform (FFT) to the grid voltage, the phase information can be calculated directly [12].…”
Section: Index Terms-small-signal Model Synchronization Impedance Mmentioning
confidence: 99%
See 1 more Smart Citation
“…Yet, this work does not explain how to obtain the synchronization angle and the effect of synchronization dynamics on the impedance measurement results. An oscillator that is synchronized to the grid voltage was adopted to generate the synchronization phase used for the impedance calculation [10], [11]. Applying the Fast Fourier Transform (FFT) to the grid voltage, the phase information can be calculated directly [12].…”
Section: Index Terms-small-signal Model Synchronization Impedance Mmentioning
confidence: 99%
“…On the other hand, it has to be sufficiently large to reject noise disturbances. In general, the magnitude of the excitation signal is chosen between 5% and 10% of steady-state values [10], [11].…”
Section: B Impedance Measurement Procedures and Algorithmmentioning
confidence: 99%
“…Analytic expressions of the grid impedance can be calculated from (18) to (20) and can be found in Appendix. Two cases are under consideration, namely Case 1 and Case 2 whose circuital parameters are given in Table II.…”
Section: B Grid Impedancementioning
confidence: 99%
“…In theory, the maximum identifiable frequency is defined by the Nyquist frequency, i.e. half the switching frequency of the inverter [14]- [20]. The lower frequency boundary, instead, is equal to the inverse of the measured time window during which the PRBS is injected.…”
Section: Performance Of the Wsi Technique And Overcoming Practicalmentioning
confidence: 99%