2007
DOI: 10.1016/j.talanta.2007.10.050
|View full text |Cite
|
Sign up to set email alerts
|

Online solid-phase extraction liquid chromatography–electrospray-tandem mass spectrometry analysis of buprenorphine and three metabolites in human urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
19
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(22 citation statements)
references
References 15 publications
2
19
1
Order By: Relevance
“…Among these, only four manuscripts describe a method for the simultaneous determination of BUP, NBUP and their glucuronides, one in plasma [36], two in urine [28, 30], and one in both matrices [24]. …”
Section: Introductionmentioning
confidence: 99%
“…Among these, only four manuscripts describe a method for the simultaneous determination of BUP, NBUP and their glucuronides, one in plasma [36], two in urine [28, 30], and one in both matrices [24]. …”
Section: Introductionmentioning
confidence: 99%
“…The LODs obtained for buprenorphine and its metabolites have been reported to be below 0.8 ng/g in the placenta and below 0.5 ng/ml in plasma and urine. A recently reported online SPE-LC-ESI/MS/MS method for urine was fast and reliable, with RSDs of 0 -10 % [26]. Only minimal ion suppression in ESI, a less than 7 % decline in the response compared with that of a pure water sample, was detected.…”
Section: Quantitative Lc/ms Analysismentioning
confidence: 95%
“…Both ESI-and APCI-based methods are utilized, thus showing the freedom of selection of suitable ionization techniques for opiates. Quantitative LC-ESI/MS/MS methods have been developed for the simultaneous determination of buprenorphine, norbuprenorphine, buprenorphine-3-glucuronide (BUP-G), and norbuprenorphine-3-glucuronide (NBUP-G) in plasma [159][160], urine [16,26], and placenta [161]. The LODs obtained for buprenorphine and its metabolites have been reported to be below 0.8 ng/g in the placenta and below 0.5 ng/ml in plasma and urine.…”
Section: Quantitative Lc/ms Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Various methods of sample preparation have also been described, including protein precipitation [40], liquid/liquid extraction [39], and solid-phase extraction [37,41,42]. The most sensitive of the above assays generally have a lower limit of quantification of approximately 0.1 ng/mL for buprenorphine and 0.25 ng/mL for norbuprenorphine, and the glucuronide metabolites are often not analyzed.…”
Section: Introductionmentioning
confidence: 99%