2013
DOI: 10.1109/tie.2012.2224078
|View full text |Cite
|
Sign up to set email alerts
|

Open- and Short-Circuit Switch Fault Diagnosis for Nonisolated DC–DC Converters Using Field Programmable Gate Array

Abstract: . (2013) 'Open-and short-circuit switch fault diagnosis for nonisolated dcdc converters using eld programmable gate array.', IEEE transactions on industrial electronics., 60 (9). pp. 4136-4146. Further information on publisher's website: Additional information: Use policyThe full-text may be used and/or reproduced, and given to third parties in any format or medium, without prior permission or charge, for personal research or study, educational, or not-for-prot purposes provided that:• a full bibliographic … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
93
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 166 publications
(93 citation statements)
references
References 25 publications
0
93
0
Order By: Relevance
“…For open-circuit switch fault detection, the method of [16,17] is used throughout this study. In this method, fault in each leg is diagnosed by comparing the measured and estimated pole voltages.…”
Section: F Fault Detection Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For open-circuit switch fault detection, the method of [16,17] is used throughout this study. In this method, fault in each leg is diagnosed by comparing the measured and estimated pole voltages.…”
Section: F Fault Detection Methodsmentioning
confidence: 99%
“…A sliding mode observer is used for fault detection in the multicell converter presented in [15]. A very fast FPGA-based fault detection using a "time and voltage criterion" is presented in [16,17]. It is capable of detecting the fault and its location in a few tens of microseconds.…”
Section: Introductionmentioning
confidence: 99%
“…For short-circuit switch faults, normally using fast acting fuses the converter topology will become similar to that after an open-switch fault [24], or special supplementary hardware is needed to detect the fault, as the software methods are not fast enough to detect the short-circuit switch faults. It is also worth to mention that many drivers have the possibility to identify the short circuited switches and stop the operation [26,27]. Nonetheless, this is not in the scope of this paper.…”
Section: Fault Detection Algorithmmentioning
confidence: 97%
“…Although most of the works in the power converter FD area address ac-dc or ac-ac converters, an increasing number of recent papers are focused on FD in dc-dc converters [78].…”
Section: Fault Diagnosis In Power Components and Convertersmentioning
confidence: 99%