2010 IEEE Radio and Wireless Symposium (RWS) 2010
DOI: 10.1109/rws.2010.5434256
|View full text |Cite
|
Sign up to set email alerts
|

Open-ended coaxial probe measurements for breast cancer detection

Abstract: We have simulated and experimentally tested a coaxial probe measuring system to be used in distinguishing between normal (healthy) breast tissue and cancerous (often malignant) breast tissue. The system employs commercially available components including an Agilent 8363B phase network analyzer (PNA) and an Agilent 85070D dielectric probe. Instead of the Agilent software three material calibration technique, we propose a four material calibration method across the frequency range of 3-17 GHz for more robust mea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0
2

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 11 publications
0
9
0
2
Order By: Relevance
“…Normal meme dokusu ile kanserli doku arasındaki ayrımı kullanarak bir koaksiyel prob ölçüm sistemiyle test yapılmıştır [18]. Aynı zamanda Şekil 7'de de gösterildiği gibi çalışmalarını bir simülasyon ortamında da gerçekleştirmişlerdir.…”
Section: şEkil 6 Deney Seti [17]unclassified
See 1 more Smart Citation
“…Normal meme dokusu ile kanserli doku arasındaki ayrımı kullanarak bir koaksiyel prob ölçüm sistemiyle test yapılmıştır [18]. Aynı zamanda Şekil 7'de de gösterildiği gibi çalışmalarını bir simülasyon ortamında da gerçekleştirmişlerdir.…”
Section: şEkil 6 Deney Seti [17]unclassified
“…Literatürde yer alan ve bu konuda yapılan çalışmalar, mikrodalga ile görüntülemenin, meme kanseri tespiti için diğe r yöntemlere göre daha Şekil 8. Koaksiyel prob ölçüm sisteminin blok şeması [18] ucuz, güvenli bir teknik olduğunu göstermektedir ve çalışmalar devam etmektedir.…”
Section: şEkil 6 Deney Seti [17]unclassified
“…Furthermore, they do not allow for continuous monitoring as they are not body-worn. Probe methods do provide accurate approximation of the dielectric constant [1], [2], but require direct access to the specimen. Therefore, they are only suitable for in vitro applications.…”
Section: Determining the Relative Permittivity Of Deep Embedded Biolomentioning
confidence: 99%
“…We propose to represent as a weighted sum of the scattering parameters measured from the multiprobe sensor at ports , where refers to the total number of measurement ports. That is (1) where is the port number, refers to the weights (to be calculated) at each port, and are the scattering parameters read across the th port. In effect, the weights in (1) need be "trained" to minimize the error in extracting , basically calibrating the system.…”
Section: Correlation Between Measured Scatteringmentioning
confidence: 99%
See 1 more Smart Citation