2013
DOI: 10.1097/bte.0000000000000004
|View full text |Cite
|
Sign up to set email alerts
|

Open Reduction and Internal Fixation of Acromion Fractures Using a Precontoured Distal Clavicle Plate

Abstract: Acromion fractures are uncommon and the indications for surgery are not well established. A variety of fixation methods have been described for the operative treatment of acromion fractures. The optimal method of fixation has not been determined. Successful results have been described with multiple techniques. We present a technique for open reduction and internal fixation of acromion fractures utilizing a precontoured plate designed for the treatment of distal clavicle fractures. We have found this to be a re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Acromion fractures of the scapula are rare: just 1% of all fractures are scapular fractures and of these only 8%–10% involve the acromion (Anavian et al, 2009 ; Tucek, 2017 ). These fractures usually occur as sequelae of high-energy injuries concomitantly with fractures of the ipsilateral glenoid, neck and body of the scapula (Almzayyen et al, 2013 ). Classification of these fractures using current systems is very difficult.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Acromion fractures of the scapula are rare: just 1% of all fractures are scapular fractures and of these only 8%–10% involve the acromion (Anavian et al, 2009 ; Tucek, 2017 ). These fractures usually occur as sequelae of high-energy injuries concomitantly with fractures of the ipsilateral glenoid, neck and body of the scapula (Almzayyen et al, 2013 ). Classification of these fractures using current systems is very difficult.…”
Section: Introductionmentioning
confidence: 99%
“…Several manufacturers market pre-contoured superior locked plates for distal complex clavicular fractures (Andersen et al, 2011 ). The plate we used, from DePuy Synthes (4528 Zuchwil, Switzerland), is well-documented to be a reliable fixation device for complex distal clavicular fractures with or without extra fixation to the coracoid process (Almzayyen et al, 2013 ; Vaishya et al, 2017 ). In our method, the osteosynthesis plate is pre-bent using a three-dimensional (3D) model of the patient’s acromion as a template.…”
Section: Introductionmentioning
confidence: 99%