2002
DOI: 10.1134/1.1529948
|View full text |Cite
|
Sign up to set email alerts
|

Open resonators for low dielectric loss measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…Therefore, we apply a new technique for measuring the loss tangent without using information on the Q-factor of the empty cavity. Namely, we use such locations of the specimen for which its planes are at maxima and minima of the standing-wave field in the cavity [18]. Such a method significantly simplifies measurements at high temperatures, which, as a result, increases measurement accuracy and reliability.…”
Section: Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…Therefore, we apply a new technique for measuring the loss tangent without using information on the Q-factor of the empty cavity. Namely, we use such locations of the specimen for which its planes are at maxima and minima of the standing-wave field in the cavity [18]. Such a method significantly simplifies measurements at high temperatures, which, as a result, increases measurement accuracy and reliability.…”
Section: Resultsmentioning
confidence: 98%
“…Studying dielectric losses in polycrystalline diamonds grown by chemical vapor deposition (CVD) has become very topical in the millimeter-wave range because of considerable progress in the growth technology and the corresponding applications of this previously "exotic" material in modern engineering [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18]. The grown diamond disks have a number of remarkable electrical and mechanical properties:…”
Section: Introductionmentioning
confidence: 99%
“…These basic equations are adequate for analysis of most experimental data, however detailed theoretical analysis [7,8] reveals small correction terms which have been included in the final data analysis.…”
Section: Resonator With Samplementioning
confidence: 99%
“…The resonator used in this project is a symmetrical interferometer, consisting of a pair of brass mirrors, coated with silver, and separated by slightly less than two radii. Extensive theoretical analysis has been done for the fields in such a structure [3][4][5][6][7][8]. From these analyses, one can express the loss tangent of a sample in terms of the loaded and unloaded Q of the resonator.…”
Section: Theorymentioning
confidence: 99%
“…Owing to a small radiation loss, "whisperinggallery" modes of the ORC like an open dielectric resonator are appropriate for studying dielectrics with minimal absorption [2]. Some theoretical models have been sufficiently developed for dielectric parameter assessment using a spherical-mirror open resonator (OR) with a plane-parallel dielectric layer placed normal to the OR axis [3]. Yet in practice, a long cylindrical object, homogeneous or stratified (e.g., optical fiber), is often the matter to deal with, including the needs of continuous parameter control during the technological process.…”
Section: Introductionmentioning