2000
DOI: 10.1039/b002173n
|View full text |Cite
|
Sign up to set email alerts
|

Open-tubular ion-exchange capillary electrochromatography of inorganic anions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
51
0
1

Year Published

2000
2000
2007
2007

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 54 publications
(52 citation statements)
references
References 19 publications
0
51
0
1
Order By: Relevance
“…The quaternary ammonium anion-exchange latex nanoparticles (Dionex AS5A) with a diameter of 65 nm had been attached electrostatically to the inner wall of the capillary, and generated the reversal EOF for the separation of inorganic anions with o-CEC [22][23][24][25]. The separation was based on anion-exchange interaction.…”
Section: Nanoparticlesmentioning
confidence: 99%
“…The quaternary ammonium anion-exchange latex nanoparticles (Dionex AS5A) with a diameter of 65 nm had been attached electrostatically to the inner wall of the capillary, and generated the reversal EOF for the separation of inorganic anions with o-CEC [22][23][24][25]. The separation was based on anion-exchange interaction.…”
Section: Nanoparticlesmentioning
confidence: 99%
“…Wall-coated capillaries for open-tubular IE-CEC can be prepared in a one-step process in which the surface silanols are modified with quaternary aminated latex particles [41,[149][150][151]. The latex particles bound electrostatically to the capillary wall introduce anion-exchange interactions with anionic analytes, the strength of which could be moderated by the type and concentration of the competing ion used in the BGE as well as the capillary diameter [149].…”
Section: Capillary Electrochromatographymentioning
confidence: 99%
“…These increased nearly two fold with 30% acetonitrile, for example, butyrophenone 101533 plates/ m. Usually higher efficiencies have been reported for less polar compounds, with 500 000 plates/m being achieved for PAHs [6,7], when significantly high concentrations of the organic modifier were used in the mobile phase. However, very low efficiencies (10 000 plates/meter) were reported for strongly interacting analytes on a 75 µm i.d OT column which were [13] attributed to the wider bore.…”
Section: Column Efficiencymentioning
confidence: 99%
“…The sol-gel is usually bonded with a C 18 chain or any other organic moiety. Using these new column fabrication methods, capillaries with internal diameters of up to 75 µm have been formed for use in CEC [13 ]. It has been possible to use such relatively wider internal diameters because of the plug-like flow profile exhibited by capillary electrochromatography.…”
Section: Introductionmentioning
confidence: 99%