2005
DOI: 10.1109/tasc.2005.849585
|View full text |Cite
|
Sign up to set email alerts
|

Operation of a 930-MHz High-Resolution NMR Magnet at TML

Abstract: A 920-MHz high-resolution NMR spectrometer has been operating at the Tsukuba Magnet Laboratory (TML) since April 2002. It has proved its effectiveness by determining the 3-D structures of protein molecules. To accelerate studies in structural biology and solid-state NMR, a second high-field NMR magnet was developed and installed at TML. Although its basic design was the same as that of the first magnet, some improvements were made. For the innermost coil, a 16%Sn-bronze-processed (Nb Ti) 3 Sn conductor was emp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
3
3
2

Relationship

2
6

Authors

Journals

citations
Cited by 36 publications
(8 citation statements)
references
References 6 publications
0
8
0
Order By: Relevance
“…Cross-section of the HTS tape is divided into 10 elements. Considering the cross-section of the HTS tape is 4.4×0.285 mm 2 , cross-section of an element is 0.44×0.285 mm 2 . In one pancake winding (Fig.…”
Section: Calculation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Cross-section of the HTS tape is divided into 10 elements. Considering the cross-section of the HTS tape is 4.4×0.285 mm 2 , cross-section of an element is 0.44×0.285 mm 2 . In one pancake winding (Fig.…”
Section: Calculation Resultsmentioning
confidence: 99%
“…A number of superconducting machines are being developed, such as, SMES (Superconducting Magnetic Energy Storage), NMR (Nuclear Magnetic Resonance), MRI (Magnetic Resonance Image) and magnetic separator [1][2][3]. Superconducting magnets are used for most of the superconducting machines.…”
Section: Introductionmentioning
confidence: 99%
“…The brass wire was wound for structural protection on the outer coil, and finally, this unit was treated with the vacuum impregnation. When the magnet was being operated in the persistent mode, the equation of the coil voltage was described as (1) The main coil involves a slight resistance . The secondary coil (self inductance ) is connected in series to the main coil (self inductance ) and coupled inductively with the primary coil (mutual inductance ).…”
Section: A Drift Compensation Unitmentioning
confidence: 99%
“…T HE Tsukuba Magnet Laboratory (TML) of the National Institute for Materials Science developed 920 MHz (21.6 T) and 930 MHz (21.8 T) NMR magnets using and NbTi wires [1]. High temperature superconductors (HTS) will be necessary to achieve an NMR magnet over 1 GHz (23.5 T).…”
Section: Introductionmentioning
confidence: 99%
“…A HIGH-SENSITIVITY and high-resolution NMR magnet, such as a 930-MHz NMR [1], is constructed using multiple and superconducting magnets. Each magnet is joined in a series by a superconducting joint between the conductor and the conductor (or the NbTi conductor) and is usually operated in the persistent mode.…”
Section: Introductionmentioning
confidence: 99%