2006
DOI: 10.1109/tpel.2006.880264
|View full text |Cite
|
Sign up to set email alerts
|

Operation of One-Cycle Controlled Three-Phase Active Power Filter With Unbalanced Source and Load

Abstract: The power quality of the ac electric system has become a great concern due to the rapidly increasing numbers of electronic equipment being connected to the grid. In order to reduce harmonic contamination in power lines and to improve its transmission efficiency, the research on active power filters (APF) has become a hot topic. Many control methods for APF were proposed in recent years. Among them, one-cycle control (OCC) has shown great promise featuring excellent harmonic suppression, simple circuitry, robus… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
28
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(28 citation statements)
references
References 17 publications
0
28
0
Order By: Relevance
“…On the other hand, to calculate average current, it is not recommended to use a pure integrative, since in practice it presents saturation problems [20]. In this sense, a low pass filter (LPF) or a peak detector is normally used [9][10][11]. Unlike aforementioned reported works, to calculate average value, in present proposal it is used a lead-lag compensator (LLC) as averaging method:…”
Section: Proposed Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, to calculate average current, it is not recommended to use a pure integrative, since in practice it presents saturation problems [20]. In this sense, a low pass filter (LPF) or a peak detector is normally used [9][10][11]. Unlike aforementioned reported works, to calculate average value, in present proposal it is used a lead-lag compensator (LLC) as averaging method:…”
Section: Proposed Controllermentioning
confidence: 99%
“…OCC was also applied in APFs, when non linear load is balanced [10]. However, when load is unbalanced, no solutions were proposed [11]. Unbalanced load is always a problem in APF, because distribution networks generally feeds single phase loads and there is no way to constrain which phase is most utilized.…”
Section: Introductionmentioning
confidence: 99%
“…The one-cycle control (OCC) method, which was developed for switching converters [12]- [22], has the ability to control the duty-ratio of switches so that the average diode-voltage is exactly equal to the control reference in each switching cycle. It completely rejects external disturbances and enables the output voltage to rapidly follow the control reference.…”
Section: Introductionmentioning
confidence: 99%
“…The control of harmonic perturbations with active power filters (APF) has become a hot topic in the power engineering field. In the past two decades, active power filters have been developed rapidly to suppress harmonics in the power distribution systems of 380V voltage grids [1]- [3]. However, the voltage grids of many power distribution systems for petroleum based power generation is 600V.…”
Section: Introductionmentioning
confidence: 99%