2005
DOI: 10.1109/tpwrs.2004.841238
|View full text |Cite
|
Sign up to set email alerts
|

Operation of Static Series Compensator Under Distorted Utility Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…In addition, to ensure a proper operation of the UPQC, the voltage across the common DC-link capacitor must be higher than peak-to-peak value of supply voltage. Besides, in order to achieve the harmonic voltage and current compensation, a complex control system and a large number of sensors at S v , L i , Sr v , F i , and dc V are generally required [8][9][10][11]. These problems result in a high system cost of UPQC and limit the application of UPQC in practice.…”
Section: Configuration Of Conventional Three-phase Upqcmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, to ensure a proper operation of the UPQC, the voltage across the common DC-link capacitor must be higher than peak-to-peak value of supply voltage. Besides, in order to achieve the harmonic voltage and current compensation, a complex control system and a large number of sensors at S v , L i , Sr v , F i , and dc V are generally required [8][9][10][11]. These problems result in a high system cost of UPQC and limit the application of UPQC in practice.…”
Section: Configuration Of Conventional Three-phase Upqcmentioning
confidence: 99%
“…3. Unlike the complex control scheme in the shunt APF of the traditional UPQC, which requires information of load current, shunt APF current, and DC-link voltage [8], the control strategy in Fig. 3 is simpler, which demands the information of the supply current and the DC-link voltage.…”
Section: Control Of the Shunt Apfmentioning
confidence: 99%
See 1 more Smart Citation
“…The SSC commercially known as dynamic voltage restores [7] is a power electronic based compensator injecting missing voltage to restore the load supply voltages during a voltage dip. If active power is supplied to the load from the SSC, it needs a source for this energy.…”
Section: Topologies Of the Sscsmentioning
confidence: 99%
“…The studies in the literature related to the SSCs [7] have used topologies with energy storage [3, 7 -10]. However, a few studied the no-storage topology [11 -14], generally the topologies with conventional uncontrolled diode bridge rectifiers have been reported.…”
Section: Introductionmentioning
confidence: 99%