Optic replacement in a novel modular intraocular lens system

Abstract: Replacement of the Harmoni optic was found to be safe and efficient compared with the control IOL, as manipulation of the capsular bag to remove haptic components is not necessary with the modular design. The base component of the modular system remained stable and centred throughout the study.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
23
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(26 citation statements)
references
References 21 publications
2
23
0
1
Order By: Relevance
“…found optic exchange in the ClarVista Harmoni ® Modular system to be easier than traditional IOL exchange with the control Alcon AcrySof SA60AT in the rabbit model at two and six weeks postoperatively (Guan et al. ). More manipulation of the capsular bag with subsequent increased stress on the zonules was required to disengage the haptics of the control lens as compared to the test lens, especially at the postoperative Week 6 exchange procedure given the accelerated proliferative capacity of rabbits (six weeks in the rabbit model correspond to roughly two years in humans) (Guan et al.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…found optic exchange in the ClarVista Harmoni ® Modular system to be easier than traditional IOL exchange with the control Alcon AcrySof SA60AT in the rabbit model at two and six weeks postoperatively (Guan et al. ). More manipulation of the capsular bag with subsequent increased stress on the zonules was required to disengage the haptics of the control lens as compared to the test lens, especially at the postoperative Week 6 exchange procedure given the accelerated proliferative capacity of rabbits (six weeks in the rabbit model correspond to roughly two years in humans) (Guan et al.…”
Section: Discussionmentioning
confidence: 99%
“…More manipulation of the capsular bag with subsequent increased stress on the zonules was required to disengage the haptics of the control lens as compared to the test lens, especially at the postoperative Week 6 exchange procedure given the accelerated proliferative capacity of rabbits (six weeks in the rabbit model correspond to roughly two years in humans) (Guan et al. ). This finding is particularly relevant to paediatric cataract surgery as multiple IOL exchanges are often required many years after the original procedure due to unpredictable degrees of myopic shift (Kraus et al.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations