2003
DOI: 10.2116/analsci.19.129
|View full text |Cite
|
Sign up to set email alerts
|

Optical Cell with a Temperature-Control Unit for a Vacuum-Ultraviolet Circular Dichroism Spectrophotometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
72
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
8

Relationship

6
2

Authors

Journals

citations
Cited by 65 publications
(73 citation statements)
references
References 10 publications
1
72
0
Order By: Relevance
“…Details of the spectrophotometer and optical cell used are available elsewhere [21,28]. The path length of the CaF 2 optical cell was adjusted using a Teflon spacer to 10 μm for the measurements from 200 to 172 nm, while no spacer was used for measurements below 172 nm in order to reduce the absorption of light by water.…”
Section: Vuvcd Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Details of the spectrophotometer and optical cell used are available elsewhere [21,28]. The path length of the CaF 2 optical cell was adjusted using a Teflon spacer to 10 μm for the measurements from 200 to 172 nm, while no spacer was used for measurements below 172 nm in order to reduce the absorption of light by water.…”
Section: Vuvcd Measurementsmentioning
confidence: 99%
“…Some previous studies have found that the VUVCD spectra are sensitive to the equilibrium structures of monosaccharides in aqueous solution, such as the gauche (G) and trans (T) conformations of the hydroxylmethyl group at C-5, and the α-and β-anomer configurations of the hydroxyl group at C-1 [3,17,24,25]. However, since the pairwise relationships between the structures and VUVCD of monosaccharides remained unclear from these experimental results, we have recently measured the VUVCD spectra of various methyl aldopyranosides including methyl α-D-glucopyranosides in aqueous solution [19,20] using a synchrotron-radiation (SR) VUVCD spectrophotometer at the Hiroshima Synchrotron Radiation Center [21,28]. Using the time-dependent density functional theory (TDDFT) and molecular dynamics (MD) simulations involving explicit water molecules [15,35,40], we theoretically revealed that the GT and GG rotamers exhibited negative and positive CD around 170 nm, respectively, while the α-and β-anomer configurations showed negative and positive CD around 160 nm, respectively [19,20].…”
Section: Introductionmentioning
confidence: 99%
“…VUVCD measurements were performed with a synchrotron-radiation VUVCD spectrophotometer at the Hiroshima Synchrotron Radiation Center (HiSOR). Details of the spectrophotometer and the optical cell with a temperature-control unit are available elsewhere [11,12]. The optical cell with CaF 2 windows was used, and no spacer was used in order to reduce the light absorption by water at lower wavelengths.…”
Section: Methodsmentioning
confidence: 99%
“…CD spectra in VUV region below 190 nm can be measured accurately by a VUVCD spectrophotometer using synchrotron radiation as an intense light source [11,12]. With the aid of the VUVCD spectroscopy, a contribution of gelatin to the CD spectra can be separated from that of sugars and χ was shown to be determined from ellipticity θ at a wavelength of 198 nm.…”
Section: Introductionmentioning
confidence: 99%
“…The details of the optical devices, sample cell, and data acquisition of the spectrophotometer were described previously. [30][31][32][33] The enzyme (141 μM) was prepared in buffer containing 10 mM sodium phosphate, pH 7.4. The secondary structure contents of ChiW-SLHd were estimated using the SELCON3 program 34) and the VUVCD spectra of the 31 reference proteins with known X-ray structures.…”
Section: Genetic Analysismentioning
confidence: 99%