Optical Coherence Tomography (OCT) Device Independent Intraretinal Layer Segmentation

Abstract: Potential application of the software includes routine clinical practice and multicenter clinical trials.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
36
0
3

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(39 citation statements)
references
References 51 publications
0
36
0
3
Order By: Relevance
“…To date, most studies in this area, and with good indications of reliability, focused in particular on healthy participants and used automatic algorithms [22][23][24][25][26][27] . However, the presence of a pathology and/or retinal manual segmentation or manual correction at certain locations are/is repeatedly referred to as essential to decrease measurement variability and to improve reproducibility [44] .…”
Section: Limitationsmentioning
confidence: 99%
“…To date, most studies in this area, and with good indications of reliability, focused in particular on healthy participants and used automatic algorithms [22][23][24][25][26][27] . However, the presence of a pathology and/or retinal manual segmentation or manual correction at certain locations are/is repeatedly referred to as essential to decrease measurement variability and to improve reproducibility [44] .…”
Section: Limitationsmentioning
confidence: 99%
“…To date, most studies, with good indications of reliability, have focused particularly on healthy participants and have used automatic algorithms [45][46][47][48][49][50]. However, in the presence of pathology, manual segmentation or manual correction at certain locations is considered essential to decrease the measurement variability and improve reproducibility [51].…”
Section: Limitationsmentioning
confidence: 99%
“…If multiple images were obtained in the same patient, the highest-quality image was segmented. The automated segmentation software (Di-OCTA [21]) allows a device-independent OCT analysis employing a consistent definition of layer boundaries and segments up to 11 intraretinal layers in OCT. The software comprises different analysis methods such as thickness profiling, thickness mapping, and layer combination.…”
Section: Optical Coherence Tomographymentioning
confidence: 99%
“…The software comprises different analysis methods such as thickness profiling, thickness mapping, and layer combination. A detailed explanation regarding the functionality of the software tool is published in Ehnes et al [21].…”