2016
DOI: 10.1109/jsen.2015.2482944
|View full text |Cite
|
Sign up to set email alerts
|

Optical MEMS Pressure Sensors Incorporating Dual Waveguide Bragg Gratings on Diaphragms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…In addition, the FBG pressure sensor’s strong antielectromagnetic interference capability and great safety are a result of its usage of optical signals for sensing. It is appropriate for pressure monitoring in areas with severe electromagnetic interference or dangerous conditions, such as the aircraft, 5 , 6 oil wells, 7 9 and pipelines 10 14 In addition, FBG pressure sensors have been implemented in biological domains, such as blood pressure monitoring, 15 17 sleep quality monitoring, 18 and plantar pressure monitoring, 19 23 among others.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the FBG pressure sensor’s strong antielectromagnetic interference capability and great safety are a result of its usage of optical signals for sensing. It is appropriate for pressure monitoring in areas with severe electromagnetic interference or dangerous conditions, such as the aircraft, 5 , 6 oil wells, 7 9 and pipelines 10 14 In addition, FBG pressure sensors have been implemented in biological domains, such as blood pressure monitoring, 15 17 sleep quality monitoring, 18 and plantar pressure monitoring, 19 23 among others.…”
Section: Introductionmentioning
confidence: 99%
“…Other pressure sensors are also available in the literature, like acoustics-based pressure sensors using surface acoustic wave (SAW) filters (Ren et al , 2016; Xie et al , 2018; Muller et al , 2017). Optical pressure sensors are also available abundantly in the literature (Neeharika and Pattnaik, 2016; Jun et al , 2012).…”
Section: Introductionmentioning
confidence: 99%
“…The transducer placed on the contact surface across the body can also impose artificially high pressures on the tissues and poor resolution due to the thickness of the transducer [15,16]. As an alternative to the electric sensor, the optical sensor has provided good durability and external noise immunity [17,18,19]. Some device measured the pressure distribution for foot plantar using optic fiber [20].…”
Section: Introductionmentioning
confidence: 99%