Biomedical Topical Meeting 2002
DOI: 10.1364/bio.2002.sue5
|View full text |Cite
|
Sign up to set email alerts
|

Optical tomography of the breast using a 32-channel time-resolved imager

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…Therefore our patient studies have been restricted to the use of single rings, which are mounted in an adjustable frame described in detail elsewhere. 18 The volunteer leans against the frame with either the left or the right breast placed in either of the two holes. The rings around the holes are of different diameters to accommodate various breast sizes.…”
Section: A Imaging Geometrymentioning
confidence: 99%
“…Therefore our patient studies have been restricted to the use of single rings, which are mounted in an adjustable frame described in detail elsewhere. 18 The volunteer leans against the frame with either the left or the right breast placed in either of the two holes. The rings around the holes are of different diameters to accommodate various breast sizes.…”
Section: A Imaging Geometrymentioning
confidence: 99%
“…) in the second term of the right hand side (rhs) of equation (7) gives the derivatives of the fluence at all mesh nodes for the previous time step. Therefore, the calculations of the Jacobian at a specific time step requires the calculation of the fluence derivatives for all mesh nodes for all previous time steps.…”
Section: Jacobian Calculationsmentioning
confidence: 99%
“…Instead, equation (7) can be solved iteratively using only the fluence rates at previous time steps and not the fluence derivatives, thereby reducing the memory storage requirements. By subsequent substitutions of the fluence derivatives of previous time steps into equation (7), the Jacobian is given by…”
Section: Jacobian Calculationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The boundary measurements of the light fluence rates due to external excitation sources can be used to reconstruct the tissue optical properties (e.g. scattering and absorption coefficients) which may give insight into tissue physiology and can be used in applications such as breast imaging [4][5][6][7][8] and brain imaging [9][10][11][12][13][14]. Different data acquisition systems can be used for DOT including continuous wave (CW), frequency domain (FD), and time domain (TD) and in general the DOT problem is ill-posed and the solution is usually obtained through an iterative minimization problem [15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%