1998
DOI: 10.1002/(sici)1098-2825(1998)12:2<115::aid-jcla7>3.0.co;2-9
|View full text |Cite
|
Sign up to set email alerts
|

Optimal conditions of immune complex transfer enzyme immunoassay for p24 antigen of HIV-1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1998
1998
2019
2019

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Similarly, immune complex transfer EIA of HIV-1 p24 antigen has been developed (11,14) and improved in sensitivity (16). Simultaneous detection of HIV-1 p24 antigen and antibody IgGs to RT and p17 antigens by immune complex transfer EIAs has shortened the window period after HIV-1 infection, during which diagnosis of the infection is not possible due to the absence of detectable antibodies to HIV-1 in the circulation (13).…”
mentioning
confidence: 83%
See 1 more Smart Citation
“…Similarly, immune complex transfer EIA of HIV-1 p24 antigen has been developed (11,14) and improved in sensitivity (16). Simultaneous detection of HIV-1 p24 antigen and antibody IgGs to RT and p17 antigens by immune complex transfer EIAs has shortened the window period after HIV-1 infection, during which diagnosis of the infection is not possible due to the absence of detectable antibodies to HIV-1 in the circulation (13).…”
mentioning
confidence: 83%
“…The previous immunoassay of HIV-1 p24 antigen in serum was modified as follows (16). An aliquot (50 l) of serum samples was incubated for 16 h with 100 l of buffer A containing 0.5 M NaCl, 100 fmol of 2,4-dinitrophenyl-biotinylbovine serum albumin-affinity-purified rabbit anti-p24 FabЈ conjugate, 5 fmol of monoclonal mouse anti-p24 FabЈ-␤-D-galactosidase conjugate, 50 g of inactive ␤-D-galactosidase, and 10 l of nonspecific rabbit serum and subsequently for 2 h with two colored polystyrene beads coated with affinity-purified (anti-2,4-dinitrophenyl group) IgG.…”
Section: Methodsmentioning
confidence: 99%
“…That is, our method also has the potential to reach limits of detection of 10 −20 mol/assay. Ishikawa and Hashida 30 , 31 have achieved the limit of detection of 10 −20 mol/assay for HIV-1 p24 by their own method, the ‘immune complex transfer enzyme immunoassay’. This method, however, requires time and effort for the detection compared with our method.…”
Section: Methodsmentioning
confidence: 99%
“…For example, an immune complex transfer enzyme immunoassay showed a limit of detection of 0.24 pg/mL (i.e., ca . 1 x 10 −17 moles/mL) [ 6 , 7 ]. A cytometric bead assay was developed to detect p24 at 0.4 pg/mL (i.e., ca .…”
Section: Introductionmentioning
confidence: 99%