2023
DOI: 10.1016/j.egyr.2023.08.066
|View full text |Cite
|
Sign up to set email alerts
|

Optimal configuration of architectural building design parameters for higher educational buildings

Salah Alghamdi,
Waiching Tang,
Sittimont Kanjanabootra
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 117 publications
0
2
0
Order By: Relevance
“…The EC required for heating and cooling, in order to maintain appropriate levels of thermal comfort, is consequently influenced by the indoor thermal environment. The 15 most significant ABDPs affecting the thermal comfort and EC of buildings were determined, as shown in Table 1, following a comprehensive review of the relevant literature [39,42]. Additionally, the selection of these parameters was based on the understanding that they have been investigated individually across various applications, involving diverse climatic zones, types of buildings, building occupancy, and outputs including thermal comfort and/or EC.…”
Section: Determination Of Architectural Building Design Parameters An...mentioning
confidence: 99%
See 1 more Smart Citation
“…The EC required for heating and cooling, in order to maintain appropriate levels of thermal comfort, is consequently influenced by the indoor thermal environment. The 15 most significant ABDPs affecting the thermal comfort and EC of buildings were determined, as shown in Table 1, following a comprehensive review of the relevant literature [39,42]. Additionally, the selection of these parameters was based on the understanding that they have been investigated individually across various applications, involving diverse climatic zones, types of buildings, building occupancy, and outputs including thermal comfort and/or EC.…”
Section: Determination Of Architectural Building Design Parameters An...mentioning
confidence: 99%
“…For example, adjusting the load shading type parameter during the conceptual design stage rather than post-construction is a more economical method for improving occupant thermal comfort and reducing EC [38]. Delaying efforts to enhance a building's performance beyond the conceptual design stage signifies a wasted opportunity to employ a more economically efficient alternative [39]. Through inputting these ABDPs, this ANN model can assist architects in estimating building performance at an early stage of architectural design, thus reducing the non-essential modelling time and enhancing the sustainability performance of architectural design.…”
Section: Introductionmentioning
confidence: 99%