2021
DOI: 10.3390/en14237883
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Control of a Doubly Fed Induction Generator of a Wind Turbine in Island Grid Operation

Abstract: Great significance is given to the use of energy from renewable sources, especially in industrial and municipal applications. The present article is devoted to the optimal control of a DFIG generator with the help of a rotor-side converter (RSC). Its aim is to ensure the delivery of the voltage of a three-phase network with appropriate parameters while operating in an islanded grid. Such a grid is usually characterized by an uneven loading of each phase. Additionally, the load of these phases changes randomly … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…e design of a 2/6 pole, 400V, 3.5 kW BDFIM with star connection for SPW, delta-star connection for APW, and nested loop rotor was carried out using BDFIM design equations and standard output equations (15)(16)(17). Table 1 lists the machine's specifications [7].…”
Section: The Hardware Model Of Bdfimmentioning
confidence: 99%
See 1 more Smart Citation
“…e design of a 2/6 pole, 400V, 3.5 kW BDFIM with star connection for SPW, delta-star connection for APW, and nested loop rotor was carried out using BDFIM design equations and standard output equations (15)(16)(17). Table 1 lists the machine's specifications [7].…”
Section: The Hardware Model Of Bdfimmentioning
confidence: 99%
“…e converter rating typically ranges between 25% and 35% of the rated power, allowing a wind turbine operation speed range of 50% to 120% of the rated speed. e authors present a control for the rotor-side converter (RSC) developed to provide symmetrical and three-phase voltage with minimal harmonic content at the islanded load terminals in [15]. e operation of an island is characterised by the uneven load on each phase and random behaviour.…”
Section: Introductionmentioning
confidence: 99%
“…10. Thus, in contrast to similar studies [30,31], the model takes into account the dependences of self and mutual inductances on the angular rotor position that increases its accuracy.…”
Section: Model Of the Electromagnetic Part Of The Studied Dtp Pm Machinementioning