2005 European Conference on Power Electronics and Applications 2005
DOI: 10.1109/epe.2005.219506
|View full text |Cite
|
Sign up to set email alerts
|

Optimal control of static VAr compensators in power supply systems with electrical arc furnaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2010
2010
2013
2013

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Because the positive reactive power at PCC means that TCR absorbs greater reactive power than the essential value, therefore, the firing angle should be increased [13], [15]. Equations (4) and 5…”
Section: Closed Loop Control Of the Tcr/fc Compensator Using Voltage mentioning
confidence: 99%
See 1 more Smart Citation
“…Because the positive reactive power at PCC means that TCR absorbs greater reactive power than the essential value, therefore, the firing angle should be increased [13], [15]. Equations (4) and 5…”
Section: Closed Loop Control Of the Tcr/fc Compensator Using Voltage mentioning
confidence: 99%
“…An improved measuring procedure was suggested to enhance TCR performance that achieves faster compensation than traditional methods. In 2003, A. Hernandez et al [3] evaluated flicker magnitudes of rapidly varying loads by means of a new frequency domain method and analytical expressions of the instantaneous flicker sensation were obtained in terms of inter-harmonic voltages and in 2005, S. Prins et al [4] presented a solution in order to obtain an optimum flicker reduction at a comparatively low capacity compensator power rating by an anti-windup extension of the controller. In this paper in order to use the measured arc voltages and currents-to describe the arc electrical behavior-a practical model of EAF based on random variables is proposed.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, a solution of obtaining an optimum flicker reduction at a comparatively low compensator power rating by an anti-windup extension of the controller is presented in Reference [2]. The dimensioning of a SVC for a steel plant grid with several operating EAF, taking the economic dimensioning of the compensator into account, is also demonstrated in this paper.…”
Section: Introductionmentioning
confidence: 96%
“…An improved measuring procedure was suggested to enhance TCR performance that it achieves faster compensation more than traditional methods [2]. In 2003, A. Hernandez et al evaluated flicker magnitudes of rapidly varying loads by means of a new frequency domain method and analytical expressions of the instantaneous flicker sensation were obtained in terms of interharmonic voltages [3] and in 2005, S. Prins et al presented a solution for how to obtain an optimum flicker reduction at a comparatively low capacity compensator power rating by an anti-windup extension of the controller [4]. In this paper by using the measured arc voltage and currents-to describe the arc electrical behavior-and by applying software, a practical model of EAF based on random variables is proposed.…”
Section: Introductionmentioning
confidence: 99%