Optimal emission enhancement in orthogonal double-pulse laser-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(16 citation statements)
references
References 40 publications
1
15
0
Order By: Relevance
“…In recent years, in order to improve the industrial application of LIBS, many researchers developed LIBS technique to enhance and stabilize laser-induced plasma, in which the use of external energy is an effective method and has been widely studied. [16][17][18] The process of steel production is extremely complicate. The changes of sample temperature and morphology are involved in this process, which will greatly affect the real-time measurement accuracy of LIBS.…”
Section: Sample Temperature Effect On Steel Measurement Using Sp-libsmentioning
confidence: 99%
“…In recent years, in order to improve the industrial application of LIBS, many researchers developed LIBS technique to enhance and stabilize laser-induced plasma, in which the use of external energy is an effective method and has been widely studied. [16][17][18] The process of steel production is extremely complicate. The changes of sample temperature and morphology are involved in this process, which will greatly affect the real-time measurement accuracy of LIBS.…”
Section: Sample Temperature Effect On Steel Measurement Using Sp-libsmentioning
confidence: 99%
“…However, a signal improvement can also be obtained by improving the conventional LIBS system, e.g. using a resonant excitation system [18] or double pulse (DP) LIBS [17,[19][20][21][22][23][24][25][26][27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…collinear, crossed beam or orthogonal, which allows preablation and reheating. In the DP LIBS orthogonal configuration the signal intensity can be increased by increasing the laser energy and/or the number of pulses without increasing the amount of ablated material [21,22,24,26,29,30]. The preservation of the physical structure of samples is particularly useful when analyzing samples in the form of soft and brittle pellets and for cultural heritage artifacts.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations