Optimal inverter VAR control in distribution systems with high PV penetration

Abstract: Abstract-The intent of the study detailed in this paper is to demonstrate the benefits of inverter var control on a fast timescale to mitigate rapid and large voltage fluctuations due to the high penetration of photovoltaic generation and the resulting reverse power flow. Our approach is to formulate the volt/var control as a radial optimal power flow (OPF) problem to minimize line losses and energy consumption, subject to constraints on voltage magnitudes. An efficient solution to the radial OPF problem is pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
221
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 298 publications
(225 citation statements)
references
References 7 publications
2
221
0
2
Order By: Relevance
“…Note that the voltage constraint we consider is taken directly from the network tolerance specifications, and is 3%. The number of violations in our simulations are consistent with previous work on these networks, e.g., [14,15]. The presence of storage or the data center is used to help avoid such violations.…”
Section: Setupsupporting
confidence: 84%
See 1 more Smart Citation
“…Note that the voltage constraint we consider is taken directly from the network tolerance specifications, and is 3%. The number of violations in our simulations are consistent with previous work on these networks, e.g., [14,15]. The presence of storage or the data center is used to help avoid such violations.…”
Section: Setupsupporting
confidence: 84%
“…The first is a 47 bus network ( Figure 1) and the second is a 56 bus network (Figure 2). Both are described in detail in [15].…”
Section: Setupmentioning
confidence: 99%
“…[8], an OPF formulation with the objective to minimize the market value of the curtailed energy of embedded wind generation is proposed. Other objectives include minimizing the voltage profile deviation from a reference [9], the transformer tap changer switching [10], or the network losses [11], [12]. Ref.…”
Section: A Literature Reviewmentioning
confidence: 99%
“…The adjustment is detailed in the extended version of this paper [16]. We also consider two practical networks of SCE, a 47-bus network [9] and a 56-bus network [24].…”
Section: A Test Distribution Networkmentioning
confidence: 99%