2019
DOI: 10.1049/iet-gtd.2018.6361
|View full text |Cite
|
Sign up to set email alerts
|

Optimal line flows based on voltage profile, power loss, cost and conductor temperature using coordinated controlled UPFC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…The SSSC operation can be considered as a specific case for the UPFC where the injected voltage is in quadrature with the line current. In addition, UPFC devices have been viewed as combinations of the SSSC and the static synchronous compensator (STATCOM) [38]. Consider the case where UPFC injects a voltage that is in quadrature with line current, with the phase angle of: φij=θi+θj±π2.\begin{equation}{\varphi _{ij}} = \frac{{{\theta _i} + {\theta _j} \pm \pi }}{2}.\end{equation}…”
Section: Linear Facts Modellingmentioning
confidence: 99%
“…The SSSC operation can be considered as a specific case for the UPFC where the injected voltage is in quadrature with the line current. In addition, UPFC devices have been viewed as combinations of the SSSC and the static synchronous compensator (STATCOM) [38]. Consider the case where UPFC injects a voltage that is in quadrature with line current, with the phase angle of: φij=θi+θj±π2.\begin{equation}{\varphi _{ij}} = \frac{{{\theta _i} + {\theta _j} \pm \pi }}{2}.\end{equation}…”
Section: Linear Facts Modellingmentioning
confidence: 99%
“…VSCs capability curve and their optimal operating points for the modified 30-bus system for minimising the power losses [35] and improving the voltage profile with coordinated UPFC [36]. In [37], a hybridised model between the dragonfly algorithm (DA) and the PSO has been presented for handling the OPF considering thyristorcontrolled series compensator (TCSC).…”
Section: Figure 11mentioning
confidence: 99%
“…In [34], a modified fractional order PSO has been presented to minimise the power losses as a single objective target. Also, modified wind driven versions have been applied for solving the OPF FIGURE 11 VSCs capability curve and their optimal operating points for the modified 30-bus system for minimising the power losses [35] and improving the voltage profile with coordinated UPFC [36]. In [37], a hybridised model between the dragonfly algorithm (DA) and the PSO has been presented for handling the OPF considering thyristorcontrolled series compensator (TCSC).…”
Section: Figurementioning
confidence: 99%