2017
DOI: 10.1002/etep.2360
|View full text |Cite
|
Sign up to set email alerts
|

Optimal placement method of multi UPFCs to damp power system oscillations

Abstract: Summary This paper proposed the placement of multi unified power flow controllers (UPFCs) using the system critical modes and residue factor to increase damping of the electromechanical oscillations in power system. For this purpose, the critical modes are used to determine the number of UPFCs and their optimal locations are determined using residue factor. Also, the dynamic model of UPFC, which is consists of a voltage source and a current source is used for small signal stability analysis. To control the par… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 46 publications
0
7
0
Order By: Relevance
“…The profile of voltage variation at bus system of IEEE 57 of double generator issue at (2,3), (2,6), (2,8), (3,9), (3,12), (6,9), and (6, 12) bus is described in Figures 22,23,24,25,26,27,28,29. At off time of DG and the suggested method, is detected voltage profile for normal method. During this generator shutdown period, we have seen profile of voltage in collapsing every bus.…”
Section: Double Generator Outagementioning
confidence: 99%
See 1 more Smart Citation
“…The profile of voltage variation at bus system of IEEE 57 of double generator issue at (2,3), (2,6), (2,8), (3,9), (3,12), (6,9), and (6, 12) bus is described in Figures 22,23,24,25,26,27,28,29. At off time of DG and the suggested method, is detected voltage profile for normal method. During this generator shutdown period, we have seen profile of voltage in collapsing every bus.…”
Section: Double Generator Outagementioning
confidence: 99%
“…Depend on IEEE 57‐bus with NSGA‐II test system, several problem along problem functions were repeated. For evolution of electromechanical motion control system, which dampens the position of multiple UPFCs using the fundamental modes and the system waste factor was submitted by Motiebirjandi et al 24 to select the number of UPFC for fundamental method and optimal location was solved using residue factor. Albatsh et al 25 was suggested UPFC method at FLC to provide UPFC problem's present controllers, provide adaptive power flow control via transmission line.…”
Section: Introductionmentioning
confidence: 99%
“…Using the modal analysis and computing the participation factors, the effective input signal was then detected in the proposed controller. It should be noted that the participation factor represents a criterion of the relative participation of the state variable i in the kth mode and is defined as (27) [ 48,49].…”
Section: Ssr Definitionmentioning
confidence: 99%
“…In this paper, a controller called the SSR to instability prevention controller (SSRIPC) is used to prevent the SSR instability. This controller has a gain block and a filter (washout) block [49], [50]. The DFIG's converters have eight controllers that the first, middle and end of them can be used to connect the proposed controller.…”
Section: Ssr Instability Prevention Controllermentioning
confidence: 99%